VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, Three Stage, Certification (NRTL): C/US, 100 to 115 V/50 to 60 Hz, 120 V/60 Hz, US Mains Cable
Representative image only

VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, Three Stage, Certification (NRTL): C/US, 100 to 115 V/50 to 60 Hz, 120 V/60 Hz, US Mains Cable

Sold by: Analisa Resources
Available Soon
Part #: 4.670 505Manufacturer #: 20736603
Estimated shipping time:Contact us via live chat or via contact us page

RM 36,756.50

See the available (1) variant product

Product overview

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors. Its documented configuration includes electrical supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz, connection: US Mains Cable, and pump design: Three-Stage.

Key Features:

  • Brand: VACUUBRAND
  • Model: MD 4C NT
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz
  • Connection: US Mains Cable
  • Pump Design: Three-Stage
  • Certification: NRTL: C/US
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: High performance even at low vacuum
  • Gas Ballast Performance: Good vacuum even with gas ballast
  • Noise and Vibration: Quiet and ultra low vibration
  • Operation: Oilfree
  • Separators: Inlet and outlet separator
  • Applications: This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors
  • Inlet Separator: The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets
  • Outlet Separator: The separator at the outlet collects condensate and avoids condensate backflow towards the pump

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.



Frequently Asked Questions

1. What is the VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable used for?

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors.

2. Is the VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable suitable for This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors?

Yes. It is designed for This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors, and offers an electrical supply of 100-115 V, 120 V, 50-60 Hz, 60 Hz to support this kind of work.

3. What electrical supply does the VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable have?

It has an electrical supply of 100-115 V, 120 V, 50-60 Hz, 60 Hz.

4. What connection and pump design does the VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable offer?

It offers US Mains Cable, three-Stage, NRTL: C/US and good chemical resistance and vapor tolerance.

5. How does the VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable compare with the KNF LIQUIPORT Diaphragm Liquid Pump U NF 300 KT.18RC US-Plug - 115V/60HZ from KNF?

For This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors, the VACUUBRAND model is the better choice, offering an electrical supply of 100-115 V, 120 V, 50-60 Hz, 60 Hz. The KNF model offers a voltage of 115V/60HZ with US plug as an alternative, while the VACUUBRAND model's US Mains Cable and three-Stage help make it a strong fit for This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors.

Product Specifications

  • HS Code #84141089
  • Connection pressure sideDN 8-10 mm
  • Connection suction sideDN 8-10 mm
  • Depth243 mm
  • Dimensions (WxDxH)319 x 243 x 374 mm
  • Flow rate3.4 m³/h
  • Power supply frequency50/60 Hz
  • Height374 mm
  • IP codeIP 40
  • Max. permitted ambient temp.40 °C
  • Max. voltage115 V
  • Min. permitted ambient temperature10 °C
  • Min. voltage100 V
  • No. of stages3
  • Noise level45 db(A)
  • Plug typeUS
  • Power supply100 ... 115 V, 50/60 Hz
  • TypeMD 4C NT 2AK
  • Type of auxiliary energyMains connection
  • Ultimate vacuum1.5 mbar
  • Ultimate vacuum with gas ballast3 mbar
  • UNSPSC40151502
  • Weight16.7 kg
  • Width319 mm