Representative Image

VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, Three Stage, Certification (NRTL): C/US, 100 to 115 V/50 to 60 Hz, 120 V/60 Hz, US Mains Cable

Max. voltage

Plug type

Power supply

Specifications

Compare models
HS Code #
84141089
Connection pressure side
DN 8-10 mm
Connection suction side
DN 8-10 mm
Depth
243 mm
Dimensions (WxDxH)
319 x 243 x 374 mm
Flow rate
3.4 m³/h
Power supply frequency
50/60 Hz
Height
374 mm
IP code
IP 40
Max. permitted ambient temp.
40 °C
Max. voltage
115 V

Alternative in-stock items

RM 36,756.50

Inc. GST

Available soon

Product description

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors. Its documented configuration includes electrical supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz, connection: US Mains Cable, and pump design: Three-Stage.

Key Features:

  • Brand: VACUUBRAND
  • Model: MD 4C NT
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz
  • Connection: US Mains Cable
  • Pump Design: Three-Stage
  • Certification: NRTL: C/US
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: High performance even at low vacuum
  • Gas Ballast Performance: Good vacuum even with gas ballast
  • Noise and Vibration: Quiet and ultra low vibration
  • Operation: Oilfree
  • Separators: Inlet and outlet separator
  • Applications: This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors
  • Inlet Separator: The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets
  • Outlet Separator: The separator at the outlet collects condensate and avoids condensate backflow towards the pump

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Chemistry diaphragm pump MD 4C NT +2AK, three stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US mains cable

Manufacturer P/N

20736603

Part Number

4.670 505

Manufacturer

VACUUBRAND​

Max. voltage

115 V

Chemical diaphragm pump MD 4C NT + 2AK three-tier certification (NRTL): C / US 230 V / 50-60 Hz, CEE power cable

Manufacturer P/N

20736600

Part Number

4.661 095

Manufacturer

VACUUBRAND​

Max. voltage

230 V

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockRM 6,490.00
UKME 1C207211029.880 936RM 6,490.00
CHME 1C207211019.880 935RM 6,490.00
USME 1C207211039.880 937RM 6,490.00

Chemistry vacuum system MZ 2C NT AK/M/D

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUMZ 2C NT + AK + M + D207327006.231 821RM 22,324.50
USMZ 2C NT + AK + M + D207327034.670 448RM 22,324.50

Frequently asked questions

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story