Representative Image

VACUUBRAND Chemistry Vacuum System MZ 2C NT +AK+M+D, Certification (NRTL): C/US, 100 to 115 V/50 to 60 Hz, 120 V/60 Hz, US Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
310 mm
Dimensions (WxDxH)
243 x 310 x 313 mm
Flow rate
2.0 m³/h
Height
313 mm
Plug type
US
Type
MZ 2C NT + AK + M + D
Ultimate vacuum
7 mbar
Ultimate vacuum with gas ballast
12 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

RM 22,324.50

Inc. GST

Available soon

Product description

The VACUUBRAND Chemistry Vacuum System MZ 2C NT +AK+M+D, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a chemistry vacuum system from VACUUBRAND designed for evacuation, evaporation, and pumping of gases and vapours in chemistry workflows. For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories where there are no requirements for condensation of solvent vapors at the outlet. Its documented configuration includes electrical supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz, connection: US Mains Cable, and certification: NRTL: C/US.

Key Features:

  • Brand: VACUUBRAND
  • Model: MZ 2C NT
  • Product Type: Chemistry Vacuum System
  • Electrical Supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz
  • Connection: US Mains Cable
  • Certification: NRTL: C/US
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: High performance even at low vacuum
  • Gas Ballast Performance: Good vacuum even with gas ballast
  • Noise and Vibration: Quiet and ultra low vibration
  • Vacuum Control: Manual vacuum control
  • Vacuum Display: Analog vacuum display
  • Operation: Oilfree
  • Applications: For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories where there are no requirements for condensation of solvent vapors at the outlet
  • Vacuum Regulation: The manual flow control valve regulates the effective pumping speed at the vacuum connection, the vacuum manometer offers an analog vacuum display
  • Application: This system is well proven for filtration
  • Inlet Separator: The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets

The VACUUBRAND Chemistry Vacuum System MZ 2C NT +AK+M+D, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports evacuation, evaporation, and pumping of gases and vapours in chemistry workflows where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Chemistry vacuum system MZ 2C NT +AK+M+D, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US mains cable

Manufacturer P/N

20732703

Part Number

4.670 448

Manufacturer

VACUUBRAND​

Plug type

US

Chemistry vacuum system MZ 2C NT + AK + M + D 230V / 50 - 60 Hz, CEE power cable

Manufacturer P/N

20732700

Part Number

6.231 821

Manufacturer

VACUUBRAND​

Plug type

EU

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockRM 6,490.00
UKME 1C207211029.880 936RM 6,490.00
CHME 1C207211019.880 935RM 6,490.00
USME 1C207211039.880 937RM 6,490.00

Frequently asked questions

It is a chemistry vacuum system from VACUUBRAND designed for evacuation, evaporation, and pumping of gases and vapours in chemistry workflows. For evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories where there are no requirements for condensation of solvent vapors at the outlet.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story