VACUUBRAND Chemical Vacuum System MD 12C NT +EK 100 to 115 V/50 to 60 Hz, US Plug

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
528 mm
Dimensions (WxDxH)
387 x 528 x 395 mm
Flow rate
12 m³/h
Height
395 mm
Plug type
US
Type
MD 12C NT + EK
Ultimate vacuum
2 mbar
Ultimate vacuum with gas ballast
4 mbar
UNSPSC
40151502
Width
387 mm

Alternative in-stock items

RM 66,236.50

Inc. GST

Available soon

Product description

The VACUUBRAND Chemical Vacuum System MD 12C NT +EK 100-115 V/50-60 Hz, US Plug is a chemistry vacuum system from VACUUBRAND designed for evacuation, evaporation, and pumping of gases and vapours in chemistry workflows. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors. Its documented configuration includes electrical supply: 100-115 V, 50-60 Hz, connection: US Plug, and chemical and vapour resistance: Good chemical resistance and vapor tolerance.

Key Features:

  • Brand: VACUUBRAND
  • Model: MD 12C NT
  • Product Type: Chemistry Vacuum System
  • Electrical Supply: 100-115 V, 50-60 Hz
  • Connection: US Plug
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: High performance even at low vacuum
  • Gas Ballast Performance: Good vacuum even with gas ballast
  • Noise and Vibration: Quiet and ultra low vibration
  • Operation: Oilfree
  • Inlet Separator: A separator at the inlet (AK) can be mounted later to this system
  • Applications: This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors
  • Solvent Recovery: The waste vapor condenser at the outlet (EK) enables near 100 percent solvent recovery

The VACUUBRAND Chemical Vacuum System MD 12C NT +EK 100-115 V/50-60 Hz, US Plug supports evacuation, evaporation, and pumping of gases and vapours in chemistry workflows where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Chemical vacuum system MD 12C NT +EK 100-115 V/50-60 Hz, US plug 2B350i

Manufacturer P/N

20743503

Part Number

4.701 125

Manufacturer

VACUUBRAND​

Plug type

US

Chemistry membrane pump MD 12C NT +EK three step, 230 V, 50-60 Hz with UK plug  2B350i

Manufacturer P/N

20743502

Part Number

9.880 967

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry membrane pump MD 12C NT +EK three step, 230 V, 50-60 Hz with CEE mains cable  2B350i

Manufacturer P/N

20743500

Part Number

9.880 965

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry membrane pump MD 12C NT +EK three step, 230 V, 50-60 Hz with Swiss plug   2B350i

Manufacturer P/N

20743501

Part Number

9.880 966

Manufacturer

VACUUBRAND​

Plug type

CH

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockRM 6,490.00
UKME 1C207211029.880 936RM 6,490.00
CHME 1C207211019.880 935RM 6,490.00
USME 1C207211039.880 937RM 6,490.00

Frequently asked questions

It is a chemistry vacuum system from VACUUBRAND designed for evacuation, evaporation, and pumping of gases and vapours in chemistry workflows. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story