Representative Image

PolyScience Circulator 7L Standard Digital heated, +10°...+170°C, 240V, 50Hz

Bath depth

Depth opening

Opening (WxD)

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Max. volume bath

Temperature

Volume bath

Width opening

Specifications

Compare models
HS Code #
84198998
Bath depth
127 mm
Depth opening
142 mm
Opening (WxD)
157 x 142 mm
Ext. dim. (WxDxH)
499 x 221 x 409 mm
Ext. depth
221 mm
Ext. height
409 mm
Ext. width
499 mm
Power supply frequency
50 Hz
Heating capacity
2.2 kW
Material bath
Stainless steel

RM 29,430.50

Inc. GST

Available soon

Product description

The PolyScience Circulator 7L Standard Digital heated is designed to provide precise temperature control from +10° to +170°C, ideal for laboratory applications requiring reliable heating and circulation. Operating at 240V and 50Hz, this circulator combines efficiency with digital control for ease of use and consistent performance.

Key Features:

  • Brand: PolyScience
  • Capacity: 7 liters
  • Temperature Range: +10° to +170°C
  • Voltage/Frequency: 240V, 50Hz
  • Control: Digital temperature control for precision
  • Application: Ideal for laboratory heating and circulation tasks

This circulator is essential for laboratories demanding reliable, accurate temperature management for a variety of scientific processes.

Downloads

Compare similar models

Circulator 7L Standard Digital heated, +10°...+170°C, 240V, 50Hz

Manufacturer P/N

SD07H170-A12E

Part Number

4.658 628

Manufacturer

PolyScience

Bath depth

127 mm

Circulator 20L, Standard Digital heated, +10...+170°C, 240V, 50Hz

Manufacturer P/N

SD20H170-A12E

Part Number

4.658 634

Manufacturer

PolyScience

Bath depth

140 mm

Circulator 28L, Standard Digital heated, +10...+170°C, 240V, 50Hz

Manufacturer P/N

SD28H170-A12E

Part Number

4.658 638

Manufacturer

PolyScience

Bath depth

140 mm

Circulator 15L, Standard Digital heated, +10...+170°C, 240V, 50Hz

Manufacturer P/N

SD15H170-A12E

Part Number

4.658 631

Manufacturer

PolyScience

Bath depth

140 mm

More items to explore

Heated Circulating Baths with Advanced Programmable (AP) Temperature Controller

ProductType of auxiliary energyHeating capacityMfr#Part#AvailabilityPrice
Mains connection2.2 kWAP15H200-A12E4.658 629RM 49,857.50
Mains connection2.2 kWAP28H200-A12E4.658 636RM 56,001.00
Mains connection2.2 kWAP20H200-A12E4.658 632RM 53,218.00
Mains connection2.2 kWAP07H200-A12E4.658 626RM 45,963.50

Heated Circulating Baths with Advanced Digital (AD) Temperature Controller

ProductType of auxiliary energyType of displayMfr#Part#AvailabilityPrice
Mains connectionLCD-TouchAD07H200-A12E4.658 627RM 35,315.50
Mains connectionLCD-TouchAD15H200-A12E4.658 630RM 39,484.50
Mains connectionLCD-TouchAD20H200-A12E4.658 633RM 44,792.00
Mains connectionLCD-TouchAD28H200-A12E4.658 637RM 48,757.50

Frequently asked questions

It is designed to provide precise temperature control from +10° to +170°C, ideal for laboratory applications requiring reliable heating and circulation. Operating at 240V and 50Hz, this circulator combines efficiency with digital control for ease of use and consistent performance.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story