Representative Image

LLG Vacuum Desiccator VDC-11, Cubic PC, 322x285x271mm

Plug type

Specifications

Compare models
HS Code #
84141089
Aspiration rate
17 ml/s
Depth
240 mm
Dimensions (WxDxH)
180 x 240 x 450 mm
Power supply frequency
50/60 Hz
Height
450 mm
Max. vacuum
600 mbar
Max. voltage
240 V
Min. vacuum
300 mbar
Min. voltage
100 V
Noise level
50 db(A)

RM 5,747.50

Inc. GST

Supplier Stock: 4
Delivery: 2-4 weeks

Product description

The LLG Vacuum Desiccator VDC-11 is a reliable and efficient solution for maintaining a moisture-free environment in laboratory settings. Constructed from high-quality cubic polycarbonate (PC), it offers durability, excellent impact resistance, and long-lasting performance. With dimensions of 322 x 285 x 271 mm, this desiccator features a vacuum chamber that ensures effective moisture control for sensitive materials. Ideal for laboratories requiring precision and controlled drying or storage conditions, it is a versatile tool for daily lab operations.

Key Features:

  • Brand: LLG Labware
  • Material: Durable polycarbonate (PC) for impact resistance
  • Dimensions: 322 x 285 x 271 mm
  • Type: Vacuum desiccator for efficient moisture control
  • Application: Drying, storing, and preserving moisture-sensitive materials
  • Packaging: Sold individually
  • Storage Design: Highly transparent, lightweight, shatterproof, and stackable
  • Grease-Free Sealing: Silicon O-ring and locking clip allow grease-free operation
  • Flow Control: Three-way stopcock for vacuum draw, release, or inert gas exchange
  • Stopcock And Hose Connection Outer Diameter: 9.5 mm
  • Vacuum Retention: Maximum vacuum of 1.3 mbar maintained for over 72 hours
  • Vacuum Monitoring: Built-in vacuum gauge
  • Light Protection: Also available in brown version with UV-blocking for light-sensitive samples

Scope of Supply

  • Vacuum gauge
  • O-ring
  • Drying agent tray
  • 2 x perforated sample trays (for VDC-11 and VDC-21 models)

Note: Please order compatible closures or accessories separately as required for your laboratory setup.

The LLG Vacuum Desiccator VDC-11 is an essential tool for laboratories that need precise moisture control, durability, and reliable long-term performance under vacuum conditions.

Accessories

Accessories for Aspirator LLG-uniVACUUSYS

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Handle, incl. single pin4112210062635836.263 583In stockRM 792.00
Bottle cap4112210062635846.263 584In stockRM 815.10
Replacement set for handle4112210062634196.263 419In stockRM 104.50
Replacement cap, complete, type Y4112210062904746.290 474In stockRM 918.50
Wall holder4112210064929816.492 981In stockRM 55.00
8-channel needle4112210062635886.263 588RM 346.50
Single channel needle4112210062635876.263 587RM 258.50
Quick coupling counterparts IN4112210062904756.290 475RM 561.00
Quick coupling counterparts OUT4112210062904766.290 476RM 693.00

Compare similar models

LLG-uniVACUUSYS Aspiration system with UK-plug

Manufacturer P/N

6263586

Part Number

6.263 586

Manufacturer

LLG Labware

Plug type

UK

LLG-uniVACUUSYS Aspiration system with EU-plug
In stock
LLG uniVACUUSYS Aspiration System, EU Plug

RM 5,797.00

Inc. GST

Manufacturer P/N

6263585

Part Number

6.263 585

Manufacturer

LLG Labware

Plug type

EU

Frequently asked questions

It is a reliable and efficient solution for maintaining a moisture-free environment in laboratory settings. Constructed from high-quality cubic polycarbonate (PC), it offers durability, excellent impact resistance, and long-lasting performance. With dimensions of 322 x 285 x 271 mm, this desiccator features a vacuum chamber that ensures effective moisture control for sensitive materials. Ideal for laboratories requiring precision and controlled drying or storage conditions, it is a versatile tool for daily lab operations.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story