Representative Image

LLG uniVACUUSYS Aspiration System, EU Plug

Plug type

Specifications

Compare models
HS Code #
84141089
Aspiration rate
17 ml/s
Depth
240 mm
Dimensions (WxDxH)
180 x 240 x 450 mm
Power supply frequency
50/60 Hz
Height
450 mm
Max. vacuum
600 mbar
Max. voltage
240 V
Min. vacuum
300 mbar
Min. voltage
100 V
Noise level
50 db(A)

RM 5,797.00

Inc. GST

Supplier Stock: 19
Delivery: 2-4 weeks

Product description

The LLG uniVACUUSYS Aspiration System is a complete vacuum aspiration solution equipped with an integrated vacuum pump and controller for precise, hands-free liquid removal in Life Science workflows. It is ideal for applications such as removing media from cell cultures, aspirating supernatants after centrifugation, and clearing wash solutions from immunoassay plates. The system automatically readjusts the set vacuum level and features a liquid level sensor for overflow protection, as well as self-closing connectors to prevent the escape of aerosols or liquids. The waste bottle and nozzle are fully autoclavable for maximum laboratory safety and hygiene.

Key Features:

  • Brand: LLG
  • Vacuum System: Integrated vacuum pump with automatic vacuum control
  • Ease of Use: Plug-and-play design with simple operation
  • Safety: Liquid level sensor to prevent overflow
  • Connections: Self-closing connectors prevent aerosol and liquid escape
  • Waste Bottle: 4 L autoclavable bottle and nozzle
  • Plug Type: EU plug

Scope of Supply:

  • LLG uniVACUUSYS Vacuum Aspiration System
  • Integrated vacuum pump
  • 4 L waste collection bottle
  • Single-channel needles
  • 8-channel needle aspirator handles
  • Adapters for 200 µL pipette tips (single & 8-channel)
  • Adapter for 1000 µL pipette tips (single)
  • Tubing and quick-connectors

This aspiration system offers a dependable, contamination-safe, and efficient solution for liquid handling in cell culture and analytical workflows, making it a valuable addition to any Life Science laboratory.

Accessories

Accessories for Aspirator LLG-uniVACUUSYS

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Handle, incl. single pin4112210062635836.263 583In stockRM 792.00
Bottle cap4112210062635846.263 584In stockRM 815.10
Replacement set for handle4112210062634196.263 419In stockRM 104.50
Quick coupling counterparts IN4112210062904756.290 475In stockRM 561.00
Quick coupling counterparts OUT4112210062904766.290 476In stockRM 693.00
Replacement cap, complete, type Y4112210062904746.290 474In stockRM 918.50
Wall holder4112210064929816.492 981In stockRM 55.00
8-channel needle4112210062635886.263 588RM 346.50
Single channel needle4112210062635876.263 587RM 258.50

Compare similar models

LLG-uniVACUUSYS Aspiration system with EU-plug
In stock
LLG uniVACUUSYS Aspiration System, EU Plug

RM 5,797.00

Inc. GST

Manufacturer P/N

6263585

Part Number

6.263 585

Manufacturer

LLG Labware

Plug type

EU

LLG-uniVACUUSYS Aspiration system with UK-plug

Manufacturer P/N

6263586

Part Number

6.263 586

Manufacturer

LLG Labware

Plug type

UK

Frequently asked questions

It is a complete vacuum aspiration solution equipped with an integrated vacuum pump and controller for precise, hands-free liquid removal in Life Science workflows. It is ideal for applications such as removing media from cell cultures, aspirating supernatants after centrifugation, and clearing wash solutions from immunoassay plates. The system automatically readjusts the set vacuum level and features a liquid level sensor for overflow protection, as well as self-closing connectors to prevent the escape of aerosols or liquids. The waste bottle and nozzle are fully autoclavable for maximum laboratory safety and hygiene.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story