Representative Image

15M X 0.25MM ID BP5MS 0.25UM

Length

int. diam

Temp. range

Film thickness

Specifications

Compare models
Manufacturer
Trajan Scientific Europe
Length
15m
int. diam
0.25mm
Temp. range
-40… 330/350°C
Film thickness
0.25µm

RM 1,620.00

Inc. GST

Supplier Stock: 1
Delivery: 2-4 weeks

Product description

5% Phenyl Polysilphenylene-siloxane. For 5% GC-MS analysis and general purpose MS analysis. Suitable replacement for: DB-5ms, ZB-5ms, Rxi-5Sil MS, VF-5ms, CP-Sil 8 CB.

Compare similar models

15M X 0.25MM ID BP5MS 0.25UM_100237327
15M X 0.25MM ID BP5MS 0.25UM

RM 1,620.00

Inc. GST

Manufacturer P/N

SGEZ-054308

Part Number

SGEZ-054308

Manufacturer

Trajan Scientific

Length

15m

20M X 0.18MM ID - BP5MS 0.18UM_100237326
20M X 0.18MM ID - BP5MS 0.18UM

RM 2,100.00

Inc. GST

Manufacturer P/N

SGEZ-054301

Part Number

SGEZ-054301

Manufacturer

Trajan Scientific

Length

20m

30M X 0.25MM ID - BP5MS 0.25UM_100237328
30M X 0.25MM ID - BP5MS 0.25UM

RM 2,770.00

Inc. GST

Manufacturer P/N

SGEZ-054310

Part Number

SGEZ-054310

Manufacturer

Trajan Scientific

Length

30m

30M X 0.32MM ID - BP20 0.25UM_100257074
30M X 0.32MM ID - BP20 0.25UM

RM 2,820.00

Inc. GST

Manufacturer P/N

SGEZ-054433

Part Number

SGEZ-054433

Manufacturer

Trajan Scientific

Length

30m

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 1,620.00