Representative Image

Vacuubrand Rotary Vane Pump RZ 2.5 Two-Stage, Small Flange with Hose Nozzle DN 10 mm for Inlet, 230 V / 50-60 Hz, UK/IN Mains Cable

Max. voltage

Plug type

Power supply

Specifications

Compare models
HS Code #
84141025
Connection pressure side
DN 8-10 mm
Connection suction side
KF DN 16
Depth
390 mm
Dimensions (WxDxH)
156 x 390 x 240 mm
Flow rate
38.33 l/min
Power supply frequency
50/60 Hz
Height
240 mm
IP code
IP 40
Max. voltage
230 V
No. of stages
2

RM 15,125.00

Inc. GST

Available soon

Product description

The Vacuubrand Rotary Vane Pump RZ 2.5 Two-Stage is designed for high-efficiency vacuum applications in laboratory environments. Featuring a two-stage configuration, this pump offers deep vacuum performance and reliability. The small flange with hose nozzle DN 10 mm allows easy integration with laboratory systems, while the UK/IN mains cable ensures safe and compatible power connection for 230 V / 50-60 Hz systems.

Key Features:

  • Brand: Vacuubrand
  • Model: Rotary Vane Pump RZ 2.5 Two-Stage
  • Stages: Two-stage design for improved vacuum depth
  • Flange: Small flange with hose nozzle DN 10 mm for easy connection
  • Voltage: 230 V / 50-60 Hz
  • Power Cable: UK/IN mains cable for safe connection
  • Application: Suitable for laboratory vacuum tasks requiring high efficiency

Scope of Supply:

  • Rotary vane pump
  • manual

This Vacuubrand rotary vane pump is the ideal solution for laboratories requiring reliable, deep vacuum performance with easy integration into existing systems.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Rotary vane pump RZ 2.5 two stage, small flange with hose nozzle DN 10 mm for inlet, 230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20798122

Part Number

4.691 572

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Rotary vane pump RZ 2.5 two stage 230 V / 50-60 Hz, CEE mains cable

Manufacturer P/N

20798120

Part Number

4.691 570

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Rotary vane pump RZ 2.5 two stage 230 V / 50-60 Hz, CH mains cable

Manufacturer P/N

20798121

Part Number

4.691 571

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Rotary vane pump RZ 2.5, two stage, inlet KF DN 16 / hose nozzle DN 10 mm, 220-230 V/50-60 Hz, 100-115 V/50-60 Hz, 120 V/60 Hz, US mains cable

Manufacturer P/N

20798126

Part Number

4.691 577

Manufacturer

VACUUBRAND​

Max. voltage

115 V

More items to explore

Rotary vane pump RE 2.5, one-stage

ProductPlug typeTypeMfr#Part#AvailabilityPrice
UKRE 2.5207971524.691 576RM 11,027.50
CHRE 2.5207971514.691 575RM 11,027.50
EURE 2.5207971504.691 574RM 11,027.50
USRE 2.5207971564.691 578RM 12,320.00

Rotary vane pump RZ 2.5, two-stage, package

Frequently asked questions

It is designed for high-efficiency vacuum applications in laboratory environments. Featuring a two-stage configuration, this pump offers deep vacuum performance and reliability. The small flange with hose nozzle DN 10 mm allows easy integration with laboratory systems, while the UK/IN mains cable ensures safe and compatible power connection for 230 V / 50-60 Hz systems.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story