Representative Image

Vacuubrand Diaphragm Pump MZ 2D NT, Two-Stage, 230 V, 50 Hz with CEE Plug

Plug type

Specifications

Compare models
Connection pressure side
G1/4"
Connection suction side
KF DN 16
Depth
246 mm
Dimensions (WxDxH)
242 x 246 x 198 mm
Flow rate
2.3 m³/h
Height
198 mm
No. of stages
2
Plug type
EU
Type
MZ 2D NT
Type of auxiliary energy
Mains connection

RM 13,915.00

Inc. GST

Available soon

Product description

The Vacuubrand Diaphragm Pump MZ 2D NT is a robust two-stage diaphragm pump designed to provide reliable and efficient vacuum performance in laboratory applications. Operating at 230 V and 50 Hz, this pump delivers stable vacuum levels with improved efficiency. With a CEE plug, it is suitable for European power systems, making it a versatile choice for labs worldwide. Its two-stage operation ensures low noise levels and reliable performance, ideal for demanding tasks in scientific research and laboratory work.

Key Features:

  • Brand: Vacuubrand
  • Type: Diaphragm pump
  • Design: Two-stage operation for enhanced vacuum performance and efficiency
  • Voltage: 230 V, 50 Hz
  • Cable Type: CEE plug for compatibility with European systems
  • Application: Ideal for laboratory vacuum applications that require high reliability
  • Noise Level: Low noise operation

The Vacuubrand MZ 2D NT diaphragm pump is a quiet, efficient, and reliable solution for laboratories requiring consistent vacuum performance across a variety of applications.

Downloads

Accessories

Sealing kit NT for chemistry diaphragm pumps NT

ProductForUNSPSCMfr#Part#AvailabilityPrice
MZ 2C NT40151502206968696.241 476RM 1,669.80
MD 4C NT40151502206968706.239 489RM 3,182.30
ME 4 NT, MZ 2 NT40151502206968609.880 902RM 1,034.55
ME 4C NT40151502206968649.880 906RM 968.00
MZ 2D NT40151502206968639.880 904RM 1,034.55
MV 2 NT / MD 4 NT40151502206968619.880 905RM 1,615.35
ME 8 NT40151502206968629.880 903RM 1,331.00
ME 8C NT40151502206968679.880 907RM 1,887.60

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Diaphragm pump MZ 2D NT two-stage, 230 V~ 50 Hz plug CEE

Manufacturer P/N

20732200

Part Number

9.880 889

Manufacturer

VACUUBRAND​

Plug type

EU

Diaphragm pump MZ 2D NT, two stage, certification (NRTL): C/US230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20732202

Part Number

4.670 432

Manufacturer

VACUUBRAND​

Plug type

UK

Diaphragm pump MZ 2D NT, two stage, certification (NRTL): C/US100-115 V/50-60 V, 120 V/60 Hz, US mains cable

Manufacturer P/N

20732203

Part Number

4.670 433

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps, Aluminium PTFE design, ME 1

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1207210009.880 930RM 4,856.50
UKME 1207210029.880 932RM 4,856.50
CHME 1207210019.880 931RM 4,856.50
USME 1207210039.880 933RM 4,856.50

Frequently asked questions

It is a robust two-stage diaphragm pump designed to provide reliable and efficient vacuum performance in laboratory applications. Operating at 230 V and 50 Hz, this pump delivers stable vacuum levels with improved efficiency. With a CEE plug, it is suitable for European power systems, making it a versatile choice for labs worldwide. Its two-stage operation ensures low noise levels and reliable performance, ideal for demanding tasks in scientific research and laboratory work.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 13,915.00

Inc. GST