Representative Image

Vacuubrand Chemistry Pumping Unit PC 201 NT with Electronic Vacuum Control, 230 V, 50 Hz, Plug CEE

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
326 mm
Dimensions (WxDxH)
243 x 326 x 402 mm
Flow rate
3.4 m³/h
Height
402 mm
Plug type
EU
Type
PC 201 NT
Ultimate vacuum
1.5 mbar
Ultimate vacuum with gas ballast
3 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

RM 39,479.00

Inc. GST

Available soon

Product description

The Vacuubrand PC 201 NT is a high-performance, oil-free chemistry pumping unit designed for efficient evacuation, evaporation, and pumping of gases and vapors in chemical, biological, and pharmaceutical laboratories. Operating at 230 V and 50 Hz, this unit delivers a maximum pumping speed of 3.4 m³/h and achieves an ultimate vacuum of 1.5 mbar. Equipped with electronic vacuum control and a CEE plug, it ensures precise vacuum regulation and compatibility with European power systems.

Key Features:

  • Brand: Vacuubrand
  • Type: Chemistry pumping unit
  • Design: Three-stage operation with four heads for efficient vacuum generation
  • Voltage: 230 V, 50 Hz
  • Plug Type: CEE plug for compatibility with European systems
  • Maximum Pumping Speed: 3.4 m³/h at 50 Hz
  • Ultimate Vacuum: 1.5 mbar
  • Ultimate Vacuum with Gas Ballast: 3 mbar
  • Noise Level: 45 dBA
  • Weight: 17.5 kg
  • Applications: Rotary evaporators, vacuum concentrators, vacuum drying ovens with high boiling solvents

The PC 201 NT features a manual flow control valve to regulate the effective pumping speed at the vacuum connection, and a vacuum manometer offers an analog vacuum display. The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets, while the exhaust waste vapor condenser enables near-100-percent solvent recovery. Its compact design, low noise level, and maintenance-free operation make it an excellent choice for various laboratory applications.

Downloads

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081RM 555.50
PVC34.9 mm206860634.714 084RM 1,138.50
PVC38.1 mm206860654.714 085RM 1,325.50
PVC15.9 mm206860614.714 082RM 643.50
PVC22.3 mm206860624.714 083RM 704.00

Compare similar models

Chemistry pumping unit PC 201 NT with electronical vacuum control, 230 V~ 50 Hz, plug CEE

Manufacturer P/N

20737000

Part Number

6.241 292

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry pumping unit PC 201 NT, with MD 4C, certification (NRTL): C/US100-115 V/50-60 V, 120 V/60 Hz, US mains cable

Manufacturer P/N

20737003

Part Number

4.670 512

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Chemistry pumping units VARIO® select PC 3016 NT

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUPC 3016 NT VARIO ® select257418504.687 921RM 87,037.50
USPC 3016 NT VARIO ® select257418534.701 144RM 87,037.50

Chemistry Pumping Unit PC 3001 VARIO® select with condenser Peltronic®

ProductTypeDepthMfr#Part#AvailabilityPrice
PC 3001 VARIO ® select EKP300 mm207002454.669 248RM 61,809.00

Frequently asked questions

It is a high-performance, oil-free chemistry pumping unit designed for efficient evacuation, evaporation, and pumping of gases and vapors in chemical, biological, and pharmaceutical laboratories. Operating at 230 V and 50 Hz, this unit delivers a maximum pumping speed of 3.4 m³/h and achieves an ultimate vacuum of 1.5 mbar. Equipped with electronic vacuum control and a CEE plug, it ensures precise vacuum regulation and compatibility with European power systems.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story