Accuracy

Capacity

Colour coding

Division

For tips

Precision

Specifications

Compare models
HS Code #
84798997
Accuracy
12,0 ± R%
Capacity
0.2 ... 2 µl
Colour coding
Pink
Division
0.002 µl
For tips
Finntip 10 Micro, Filter 10 Micro, Flex 10, Flex Filter 10
No. of channels
1
Precision
2,0 ≤·VK%
UNSPSC
41121504

Alternative in-stock items

RM 2,238.50

Inc. GST

Available soon

Product description

The Thermo Finnpipette F1, 1-channel variable volume 0.2-2µl micro, is designed for precise pipetting of extremely small volumes in laboratory settings. With a variable volume range from 0.2µl to 2µl, this pipette provides excellent accuracy and control for handling micro-volume samples. Ideal for applications that require precision, the Finnpipette F1 offers reliable performance, especially when used with Thermo Finn pipette tips for optimal results.

Key Features:

  • Brand: Thermo Scientific
  • Volume Range: Variable volume from 0.2µl to 2µl for micro-volume handling
  • Compatibility: Designed to work seamlessly with Thermo Finn pipette tips
  • Application: Ideal for precise liquid handling in molecular biology, genomics, and other research applications requiring micro volumes
  • Durability: Built for long-lasting, dependable performance

The Thermo Finnpipette F1 is an essential tool for laboratories that require precise control over extremely small liquid volumes, ensuring accurate results for high-precision applications.

Downloads

Accessories

Pipette stand for single and multichannel microliter pipettes F1 / F2

ProductColourFor multi-channel pipettesMfr#Part#AvailabilityPrice
WhiteYes94204009.282 440In stockRM 847.00

Compare similar models

Finnpipette F1, 1-channel variable volume 0,2-2µl, micro

Manufacturer P/N

4641010N

Part Number

4.658 787

Manufacturer

Thermo Scientific

Accuracy

12,0 ± R%

Finnpipette F1, 1-channel variable volume 500-5000µl

Manufacturer P/N

4641110N

Part Number

4.658 797

Manufacturer

Thermo Scientific

Accuracy

2,0 ± R%

Finnpipette F1, 1-channel variable volume 1-10µl, micro

Manufacturer P/N

4641030N

Part Number

4.658 789

Manufacturer

Thermo Scientific

Accuracy

2,5 ± R%

Finnpipette F1, 1-channel variable volume 1-10µl

Manufacturer P/N

4641040N

Part Number

4.658 790

Manufacturer

Thermo Scientific

Accuracy

3,5 ± R%

Finnpipette F1, 1-channel variable volume 20-200µl

Manufacturer P/N

4641080N

Part Number

4.658 794

Manufacturer

Thermo Scientific

Accuracy

1,8 ± R%

Finnpipette F1, 1-channel variable volume 100-1000µl

Manufacturer P/N

4641100N

Part Number

4.658 796

Manufacturer

Thermo Scientific

Accuracy

1,0 ± R%

Finnpipette F1, 1-channel variable volume 5-50µl, micro

Manufacturer P/N

4641130N

Part Number

4.658 799

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F1, 1-channel variable volume 2-20µl

Manufacturer P/N

4641060N

Part Number

4.658 792

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F1, 1-channel variable volume 10-100µl

Manufacturer P/N

4641070N

Part Number

4.658 793

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F1, 1-channel variable volume 0,5-5µl, micro

Manufacturer P/N

4641020N

Part Number

4.658 788

Manufacturer

Thermo Scientific

Accuracy

6,0 ± R%

Finnpipette F1, 1-channel variable volume 5-50µl

Manufacturer P/N

4641140N

Part Number

4.658 800

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F1, 1-channel variable volume 30-300µl

Manufacturer P/N

4641090N

Part Number

4.658 795

Manufacturer

Thermo Scientific

Accuracy

1,5 ± R%

Finnpipette F1, 1-channel variable volume 1000-10000µl

Manufacturer P/N

4641120N

Part Number

4.658 798

Manufacturer

Thermo Scientific

Accuracy

2,0 ± R%

Finnpipette F1, 1-channel variable volume 2-20µl, micro

Manufacturer P/N

4641050N

Part Number

4.658 791

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Frequently asked questions

It is designed for precise pipetting of extremely small volumes in laboratory settings. With a variable volume range from 0.2µl to 2µl, this pipette provides excellent accuracy and control for handling micro-volume samples. Ideal for applications that require precision, the Finnpipette F1 offers reliable performance, especially when used with Thermo Finn pipette tips for optimal results.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story