Representative Image

SOCOREX Acura Manual 855, 40–350 µl Multichannel Pipet Adjustable 8 Channel, Autoclavable

Brand:Socorex

Accuracy

Capacity

Division

For tips

No. of channels

Precision

Specifications

Compare models
HS Code #
84798997
Accuracy
0,8 ± R%
Autoclavable
Yes
Capacity
40 ... 350 µl
Division
0.4 µl
For tips
350 µl
No. of channels
8
Precision
0,3 ≤·VK%
UNSPSC
41121504
Warranty
3 years

RM 4,191.00

Inc. GST

Available soon

Product description

The SOCOREX Acura Manual 855 is an adjustable multichannel pipette offering precise volume control from 40 to 350 µl. Designed with 8 channels, this pipette ensures efficient and simultaneous liquid handling, making it ideal for high-throughput laboratory applications. Fully autoclavable for optimal sterilization, the ergonomic design ensures comfort during prolonged use and accurate pipetting results.

Key Features:

  • Brand: SOCOREX
  • Model: Acura Manual 855
  • Volume Range: Adjustable from 40 to 350 µl
  • Channels: 8-channel configuration for multichannel pipetting
  • Sterilization: Fully autoclavable for contamination-free operation
  • Application: Ideal for routine liquid handling in laboratories
  • Packaging: Supplied as a single unit

The SOCOREX Acura Manual 855 multichannel pipette combines precision, ergonomics, and sterilization safety for reliable performance in busy lab environments.

Downloads

Accessories

Pipette stand for Single and Multichannel microliter pipettes, for Calibra® and Acura® models

ProductMaterialFor pipettes brandMfr#Part#AvailabilityPrice
PACalibra®, Acura®320.3409.411 505RM 869.00

Compare similar models

Acura® manual 855, 40 - 350 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.350

Part Number

9.411 633

Manufacturer

Socorex

Accuracy

0,8 ± R%

Acura® manual 855, 5 - 50 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.050

Part Number

9.411 631

Manufacturer

Socorex

Accuracy

0,8 ± R%

Acura® manual 855, 20 - 200 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.200

Part Number

9.411 632

Manufacturer

Socorex

Accuracy

0,7 ± R%

Acura® manual 855, 10 - 100 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.100

Part Number

6.286 775

Manufacturer

Socorex

Accuracy

0,8 ± R%

Acura® manual 855, 5 - 50 µl multichannel pipet adjustable 12 channel, autoclavable

Manufacturer P/N

855.12.050

Part Number

9.411 635

Manufacturer

Socorex

Accuracy

0,8 ± R%

Acura® manual 855, 0,5 - 10 µl multichannel pipet adjustable 12 channel, autoclavable

Manufacturer P/N

855.12.010

Part Number

9.411 634

Manufacturer

Socorex

Accuracy

1,5 ± R%

Acura® manual 855, 20 - 200 µl multichannel pipet adjustable 12 channel, autoclavable

Manufacturer P/N

855.12.200

Part Number

9.411 636

Manufacturer

Socorex

Accuracy

0,7 ± R%

Acura® manual 855, 40 - 350 µl multichannel pipet adjustable 12 channel, autoclavable

Manufacturer P/N

855.12.350

Part Number

9.411 637

Manufacturer

Socorex

Accuracy

0,8 ± R%

Acura® manual 855, 0.5 - 10 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.010

Part Number

9.411 630

Manufacturer

Socorex

Accuracy

1,5 ± R%

Acura® manual 855, 2 - 20 µl multichannel pipet adjustable 8 channel, autoclavable

Manufacturer P/N

855.08.020

Part Number

6.323 679

Manufacturer

Socorex

Accuracy

1,2 ± R%

Frequently asked questions

It is an adjustable multichannel pipette offering precise volume control from 40 to 350 µl. Designed with 8 channels, this pipette ensures efficient and simultaneous liquid handling, making it ideal for high-throughput laboratory applications. Fully autoclavable for optimal sterilization, the ergonomic design ensures comfort during prolonged use and accurate pipetting results.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story