SI Analytics Standard Buffer Solutions, pH 9.18, L 4799, 60 Ampoules

pH value (25°C)

Specifications

Compare models
No. of packages
60
Package capacity
17 ml
pH value (25°C)
9.18
Container type
Ampoule
Content
60 x Ampoule of 17 ml
UNSPSC
41116166

RM 1,831.50

Inc. GST

Available soon

Product description

The SI Analytics Standard Buffer Solutions, pH 9.18, L 4799, 60 Ampoules, are designed for accurate calibration of pH measurement systems in laboratory and analytical environments. Manufactured in accordance with DIN 19266 standards, these buffer solutions provide consistent and reliable calibration in the alkaline range. Supplied in double-end ampoules, each portion is protected from contamination, ensuring high measurement accuracy and repeatability.

Key Features:

  • Brand: SI Analytics
  • DIN 19266 compliant calibration solution: Produced according to recognised standards, ensuring dependable and standardised pH calibration performance.
  • pH 9.18 buffer solution: Ideal for calibrating pH meters in the alkaline range, supporting accurate measurements across a wide range of applications.
  • Double-end ampoule design: Provides excellent protection against contamination, ensuring the solution remains pure until use and supporting reliable calibration results.
  • Hot steam sterilised: Enhances solution stability and shelf life, making it suitable for long-term storage and consistent laboratory use.
  • Preservative-free formulation: Eliminates the risk of interference from added chemicals, supporting accurate and reproducible calibration.
  • Supplied with manufacturer certificate: Provides traceability and quality assurance for laboratory and regulated environments.
  • Convenient ampoule format: Each 20 mL ampoule contains approximately 17 mL of solution, allowing controlled single-use application.
  • Pack of 60 ampoules: Suitable for laboratories with frequent calibration requirements and high-throughput workflows.

The SI Analytics Standard Buffer Solutions, pH 9.18, are a reliable choice for laboratories requiring accurate, contamination-protected, and traceable calibration standards. When you source through LabFriend, you gain access to trusted laboratory consumables, dependable supply, and support in selecting the right calibration products for your workflow. Choose LabFriend for pH buffer solutions that help maintain measurement accuracy, consistency, and operational efficiency.

Compare similar models

Standard buffer solutions pH 9.18, L 4799 60 ampoules

Manufacturer P/N

285138262

Part Number

7.022 799

Manufacturer

SI Analytics

pH value (25°C)

9.18

Standard buffer solutions L 4791 60 ampoules

Manufacturer P/N

285137977

Part Number

7.022 771

Manufacturer

SI Analytics

pH value (25°C)

1.68

Standard buffer solutions pH 4.01, L 4794 60 ampoules

Manufacturer P/N

285138246

Part Number

9.774 342

Manufacturer

SI Analytics

pH value (25°C)

4.01

Standard buffer solutions pH 6.87, L 4796 60 ampoules

Manufacturer P/N

285138254

Part Number

9.774 344

Manufacturer

SI Analytics

pH value (25°C)

6.87

Frequently asked questions

It are designed for accurate calibration of pH measurement systems in laboratory and analytical environments. Manufactured in accordance with DIN 19266 standards, these buffer solutions provide consistent and reliable calibration in the alkaline range. Supplied in double-end ampoules, each portion is protected from contamination, ensuring high measurement accuracy and repeatability.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 1,831.50

Inc. GST