Representative Image

SCAT SafetyWasteCap S65 4x2.3/3.2mm AD, 1x6.4mm ID (Leak)

Brand:SCAT

Capillary connections

No. of fittings

No. of olives

Specifications

Compare models
HS Code #
39269097
Capillary connections
4
Connection for exhaust filter
1
Hose connections
1
Material
PTFE
No. of fittings
4 x 1,6/ 2,3/ 3,2 mm
No. of olives
1
Thread
S 65
UNSPSC
41115700

RM 1,287.00

Inc. GST

Available soon

Product description

The SCAT SafetyWasteCap S65 is designed for secure sealing and safe disposal of laboratory waste. Featuring four 2.3mm and 3.2mm outer diameter (OD) connectors and one 6.4mm inner diameter (ID) leak connector, this cap offers leak-proof performance for hazardous materials. The durable construction ensures long-lasting chemical resistance, making it ideal for laboratory settings that require safe and secure handling of waste liquids and gases.

Key Features:

  • Brand: SCAT
  • Connector Type: Four 2.3mm/3.2mm OD connectors and one 6.4mm ID leak connector
  • Material: Durable construction for leak-proof sealing and chemical resistance
  • Application: Suitable for safe laboratory waste disposal and fluid containment

Scope of Supply:

  • Safety Waste Cap
  • PFA fittings
  • Hose olive

This SafetyWasteCap S65 ensures secure sealing and efficient waste handling, essential for laboratories dealing with hazardous substances.

Accessories

Exhaust filters V3.0, with change indicator

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockRM 588.50
PTFEWhite1079929.139 882RM 599.50
PTFEWhite1079919.139 883RM 599.50
PTFEWhite1079934.005 639RM 599.50
PPColourless1079954.005 641RM 588.50
PPColourless1079964.005 642RM 588.50
PPColourless1079944.005 640RM 588.50
PPColourless1070934.005 477RM 588.50
PPColourless1070794.005 463RM 830.50
PPColourless1070904.005 474RM 588.50
PPColourless1070284.005 433RM 588.50
PTFEWhite1170304.005 789RM 599.50
PPColourless1070954.005 479RM 588.50
PPColourless1070924.005 476RM 588.50
PTFEWhite1070724.005 456RM 830.50
PPColourless1070944.005 478RM 352.00
PPColourless1070864.005 470RM 588.50
PPColourless1070974.005 481RM 599.50
PPColourless1070744.005 458RM 649.00
PPColourless1070854.005 469RM 588.50
PPColourless1070894.005 473RM 588.50
PPColourless1070914.005 475RM 467.50
PPColourless1070964.005 480RM 588.50
PPColourless1070714.005 950RM 706.20
PPColourless1070844.005 468RM 599.50

Compare similar models

SafetyWasteCap S65 4x2.3/3.2mm AD, 1x6.4mm ID (Leak)
Available soon
SCAT SafetyWasteCap S65 4x2.3/3.2mm AD, 1x6.4mm ID (Leak)

RM 1,287.00

Inc. GST

Manufacturer P/N

108047

Part Number

4.005 686

Manufacturer

SCAT

Capillary connections

4

SafetyWasteCap S65 5x2.3/3.2mm OD
Available soon
SCAT SafetyWasteCap S65 5x2.3/3.2mm OD

RM 1,287.00

Inc. GST

Manufacturer P/N

108046

Part Number

4.005 685

Manufacturer

SCAT

Capillary connections

5

Frequently asked questions

It is designed for secure sealing and safe disposal of laboratory waste. Featuring four 2.3mm and 3.2mm outer diameter (OD) connectors and one 6.4mm inner diameter (ID) leak connector, this cap offers leak-proof performance for hazardous materials. The durable construction ensures long-lasting chemical resistance, making it ideal for laboratory settings that require safe and secure handling of waste liquids and gases.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story