Representative Image

SCAT SafetyCap II, V2.0, GL45 2x PFA-fitting 3.2 OD, 90° angled + ventilation valve

Brand:SCAT

Capillary connections

No. of fittings

Specifications

Compare models
Capillary connections
2
Material
PPS/PTFE
No. of fittings
2 x 1,6/ 2,3/ 3,2 mm
Thread
GL 45
UNSPSC
41115700

RM 918.50

Inc. GST

Available soon

Product description

The SCAT SafetyCap II, V2.0, GL45 with 2x PFA fittings (3.2 mm OD) and a 90° angled ventilation valve provides a secure and chemically resistant solution for solvent handling. Made from PPS/PTFE, it offers excellent durability and compatibility with HPLC systems. This cap includes an integrated air valve, change indicator, and labelling field for enhanced functionality and safety in laboratory environments.

Key Features:

  • Brand: SCAT
  • Thread Size: GL45
  • Material: PPS/PTFE for robust chemical resistance
  • Fittings: 2x PFA fittings (3.2 mm OD)
  • Ventilation: 90° angled air valve with change indicator
  • Application: Ideal for HPLC and solvent safety systems

Scope of Supply:

  • Safety Cap
  • Air valve
  • Change indicator
  • PFA fittings
  • PFA blind plug
  • Labelling field

This SCAT SafetyCap is an essential component for any lab handling aggressive solvents. It promotes operational safety, minimizes evaporation, and supports long-term performance with minimal maintenance.

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockRM 588.50
PTFEWhite1079929.139 882RM 599.50
PTFEWhite1079919.139 883RM 599.50
PTFEWhite1079934.005 639RM 599.50
PPColourless1079954.005 641RM 588.50
PPColourless1079964.005 642RM 588.50
PPColourless1079944.005 640RM 588.50
PPColourless1070934.005 477RM 588.50
PPColourless1070794.005 463RM 830.50
PPColourless1070904.005 474RM 588.50
PPColourless1070284.005 433RM 588.50
PTFEWhite1170304.005 789RM 599.50
PPColourless1070954.005 479RM 588.50
PPColourless1070924.005 476RM 588.50
PTFEWhite1070724.005 456RM 830.50
PPColourless1070944.005 478RM 352.00
PPColourless1070864.005 470RM 588.50
PPColourless1070974.005 481RM 599.50
PPColourless1070744.005 458RM 649.00
PPColourless1070854.005 469RM 588.50
PPColourless1070894.005 473RM 588.50
PPColourless1070914.005 475RM 467.50
PPColourless1070964.005 480RM 588.50
PPColourless1070714.005 950RM 706.20
PPColourless1070844.005 468RM 599.50

Air valves Generation 2.0 for SafetyCaps

ProductColourShelf lifeMfr#Part#AvailabilityPrice
Red6 months3170104.669 375In stockRM 297.00
Red6 months3970504.669 377In stockRM 6,880.50
Red6 months3970104.669 376In stockRM 1,595.00
Red6 months3970086.318 227In stockRM 1,347.50
Red6 months3971004.683 899In stockRM 9,636.00

Compare similar models

SafetyCap II, V2.0, GL45 2x PFA-fitting 3.2 OD, 90° angled + ventilation valve

Manufacturer P/N

399909

Part Number

4.681 070

Manufacturer

SCAT

Capillary connections

2

SafetyCap I, V2.0, GL45, 1x PFA-fitting
Available soon
SCAT SafetyCap I, V2.0, GL45 with 1x PFA-fitting

RM 1,100.00

Inc. GST

Manufacturer P/N

399019

Part Number

4.681 069

Manufacturer

SCAT

Capillary connections

1

Frequently asked questions

It provides a secure and chemically resistant solution for solvent handling. Made from PPS/PTFE, it offers excellent durability and compatibility with HPLC systems. This cap includes an integrated air valve, change indicator, and labelling field for enhanced functionality and safety in laboratory environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 918.50

Inc. GST