Representative Image

SCAT Funnel, with Ball "ARNOLD" V2.0 GL45 Electrostatic Conductive

Brand:SCAT

Thread

With lance

Specifications

Compare models
HS Code #
39269097
Colour
Black
Electrically conductive
Yes
Funnel Ø
200 mm
Length lance
220 mm
Material
HDPE
Thread
GL 45
UNSPSC
41121809
With lance
No

RM 1,577.40

Inc. GST

Available soon

Product description

The SCAT Funnel with Ball "ARNOLD" V2.0 GL45 is designed for safe and controlled solvent transfer in laboratory environments. Featuring a GL45 thread, it ensures a secure and leak-proof connection to compatible lab containers. The built-in ball valve prevents spills and controls vapor emissions during use. Made from electrostatic conductive material, this funnel minimizes the risk of static discharge, offering enhanced safety when handling flammable liquids. It is an essential tool for labs focused on safety and precision in waste management and solvent disposal.

Key Features:

  • Brand: SCAT
  • Model: Funnel with Ball "ARNOLD" V2.0
  • Thread: GL45 for a secure connection with lab containers
  • Material: Electrostatic conductive to prevent static discharge
  • Design: Integrated ball valve to prevent spills and vapor release
  • Application: Ideal for safe liquid transfer and solvent disposal in laboratories

The SCAT Funnel with Ball "ARNOLD" V2.0 GL45 ensures safe, spill-free solvent transfer with electrostatic protection, making it an essential tool for modern laboratories.

Downloads

Accessories

Replacement sieve incl. splash guard for funnel ARNOLD

ProductMaterialColourMfr#Part#AvailabilityPrice
HDPEBlue3176406.324 841RM 422.40
HDPEBlack3176204.692 388RM 534.60

Compare similar models

Funnel with ball "ARNOLD", V2.0, GL45 electrostatic conductive

Manufacturer P/N

317638

Part Number

4.682 015

Manufacturer

SCAT

Thread

GL 45

Funnel with ball "ARNOLD", V2.0, S60/61 electrostatic conductive

Manufacturer P/N

317621

Part Number

4.682 004

Manufacturer

SCAT

Thread

S 60/61

Funnel with ball "ARNOLD", V2.0, GL45 electrostatic conductive

Manufacturer P/N

317622

Part Number

4.682 005

Manufacturer

SCAT

Thread

GL 45

Funnel with ball "ARNOLD", V2.0, S90, electrostatic conductive

Manufacturer P/N

317623

Part Number

4.682 006

Manufacturer

SCAT

Thread

S 90

Funnel with ball "ARNOLD", V2.0, S51, electrostatic conductive

Manufacturer P/N

317624

Part Number

4.682 007

Manufacturer

SCAT

Thread

S 51

Funnel with ball "ARNOLD", V2.0, S55, electrostatic conductive

Manufacturer P/N

317625

Part Number

4.682 008

Manufacturer

SCAT

Thread

S 55

Funnel with ball "ARNOLD", V2.0, S65, electrostatic conductive

Manufacturer P/N

317626

Part Number

4.682 009

Manufacturer

SCAT

Thread

S 65

Funnel with ball "ARNOLD", V2.0, B83, electrostatic conductive

Manufacturer P/N

317627

Part Number

4.682 010

Manufacturer

SCAT

Thread

B 83

Funnel with ball "ARNOLD", V2.0, S70/71, electrostatic conductive

Manufacturer P/N

317628

Part Number

4.682 011

Manufacturer

SCAT

Thread

S 70/71

Funnel with ball "ARNOLD", V2.0, S50, electrostatic conductive

Manufacturer P/N

317629

Part Number

4.682 012

Manufacturer

SCAT

Thread

S 50

Funnel with ball "ARNOLD", V2.0, R2", electrostatic conductive

Manufacturer P/N

317630

Part Number

4.682 013

Manufacturer

SCAT

Thread

R2" BSP/G2" + 2" TriSure

Frequently asked questions

It is designed for safe and controlled solvent transfer in laboratory environments. Featuring a GL45 thread, it ensures a secure and leak-proof connection to compatible lab containers. The built-in ball valve prevents spills and controls vapor emissions during use. Made from electrostatic conductive material, this funnel minimizes the risk of static discharge, offering enhanced safety when handling flammable liquids. It is an essential tool for labs focused on safety and precision in waste management and solvent disposal.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story