Representative Image

Peak Scientific Gas Generator Precision Zero Air, 1.5L (230 V)

Dimensions (WxDxH)

Height

Max. pressure

Type

Weight

Specifications

Compare models
HS Code #
84051000
Depth
540 mm
Dimensions (WxDxH)
380 x 540 x 156 mm
Power supply frequency
50/60 Hz
Height
156 mm
Max. pressure
5.5 bar
Max. voltage
230 V
Power supply
230 V, 50/60 Hz
Type
Precision Zero Air 1.5L
Type of auxiliary energy
Mains connection
UNSPSC
41115700

RM 24,596.00

Inc. GST

Available soon

Product description

The Peak Scientific Gas Generator Precision Zero Air 1.5L (230v) is engineered for laboratory applications requiring high-purity zero air. Designed to support analytical instruments such as gas chromatographs, this generator provides a reliable and consistent source of hydrocarbon-free air. With a compact design and 1.5L output capacity, it is perfect for labs that need efficiency, safety, and performance. It generates clean, dry, and hydrocarbon-free air with hydrocarbon content less than 0.05 ppm, meeting purity requirements for trace analysis and flame ionization detectors (FIDs) in GC.

Key Features:

  • Brand: Peak Scientific
  • Output: 1.5L
  • Voltage: 230v
  • Type: Precision Zero Air Generator
  • Application: Ideal for gas chromatography and other lab instrumentation
  • Design: Compact and reliable for continuous operation
  • Gas Purification: Fail-safe, continuous zero air generation
  • Accuracy: Modular design compatible with other PEAK Precision devices
  • Maintenance: Minimal maintenance required
  • Replacement: No replacement of catalyst chamber needed
  • Equipment Compatibility: Compatible with Precision Air Compressor
  • Display: Status display for easy monitoring

Scope of Supply:

  • Zero air generator
  • 3 m PTFE tubing
  • 1/4" compression fitting
  • 1/8" compression fitting
  • Mains power cable for EU, UK, and US

The Peak Scientific Zero Air Generator is an essential tool for any lab requiring consistent and clean air supply for precise analytical work.

Compare similar models

Gas Generator Precision Zero Air 1.5L (230v)

Manufacturer P/N

60-1500

Part Number

4.669 281

Manufacturer

Peak Scientific

Dimensions (WxDxH)

380 x 540 x 156 mm

Gas Generator Precision Zero Air 30L (230v)

Manufacturer P/N

60-0030

Part Number

4.669 285

Manufacturer

Peak Scientific

Dimensions (WxDxH)

380 x 540 x 405 mm

Gas Generator Precision Zero Air 7L (230v)

Manufacturer P/N

60-0007

Part Number

4.669 283

Manufacturer

Peak Scientific

Dimensions (WxDxH)

380 x 540 x 256 mm

Gas Generator Precision Zero Air 3.5L (230v)

Manufacturer P/N

60-3500

Part Number

4.669 282

Manufacturer

Peak Scientific

Dimensions (WxDxH)

380 x 540 x 156 mm

Gas Generator Precision Zero Air 18L (230v)

Manufacturer P/N

60-0018

Part Number

4.669 284

Manufacturer

Peak Scientific

Dimensions (WxDxH)

380 x 540 x 256 mm

Frequently asked questions

The Precision Zero Air Generator is designed for gas chromatography and other lab instrumentation. This precision zero air generator format supports routine laboratory work in that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story