Representative Image

Ohaus Analog Dry Block Heater, 4 Block, EU Plug

Brand:OHAUS

Depth

Dimensions (WxDxH)

No. of exchangeable blocks

Temperature stability

Type

Weight

Specifications

Compare models
Depth
429 mm
Dimensions (WxDxH)
203 x 429 x 89 mm
Power supply frequency
50/60 Hz
Height
89 mm
Max. voltage
230 V
No. of exchangeable blocks
4
Plug type
EU
Power supply
230 V, 50/60 Hz
Temperature stability
±2,5 °C (37 °C)
Temperature uniformity
±0,4 °C (37 °C)

RM 5,538.50

Inc. GST

Available soon

Product description

The Ohaus Analog Dry Block Heater is designed for precise and reliable heating in laboratory applications. This 4-block unit offers exceptional temperature stability and uniformity, making it ideal for processes such as enzyme reactions, incubation, and nucleic acid denaturation.

Key Features:

  • Brand: Ohaus
  • Temperature Range: Low: Ambient +5°C to 100°C; High: 75°C to 150°C
  • Temperature Stability: ±2°C
  • Uniformity Within Block: ±0.1°C at 37°C
  • Uniformity Across Blocks: ±0.2°C at 37°C
  • Heat Up Time: 23 minutes to 100°C
  • Control: Analog
  • Dimensions: 42.9 cm x 20.3 cm x 8.9 cm (L x W x H)
  • Weight: 3.8 kg
  • Power: 230V, 1.35A, 50/60Hz
  • Power Consumption: 310W
  • Safety Certification: CE; TUV

Note: Without blocks. Please order separately.

This dry block heater is an essential tool for laboratories requiring efficient and consistent heating solutions.

Accessories

Blocks for Microcentrifuge and Centrifuge tubes for Dry Block Heaters

ProductFor type of vesselsMaterial blockMfr#Part#AvailabilityPrice
TubesAluminium304001574.659 841RM 885.50
Corning Tubes ®Aluminium304001924.659 876RM 885.50
TubesAluminium304001594.659 843RM 885.50
Conical tubesAluminium304001684.659 852RM 885.50
Eppendorf Tubes ®Aluminium304001624.659 846RM 885.50
Eppendorf Tubes ®Aluminium304001914.659 875RM 885.50
Conical tubesAluminium304001724.659 856RM 885.50

Blocks and Combination Blocks for Standard Test Tubes for Dry Block Heaters

ProductFor type of vesselsMaterial blockMfr#Part#AvailabilityPrice
TubesAluminium304001654.659 849RM 885.50
TubesAluminium304001554.659 839RM 885.50
TubesAluminium304001514.659 835RM 885.50
TubesAluminium304001524.659 836RM 885.50
TubesAluminium304001534.659 837RM 885.50
TubesAluminium304001954.659 879RM 885.50
TubesAluminium304001584.659 842RM 885.50
TubesAluminium304001544.659 838RM 885.50
TubesAluminium304001564.659 840RM 885.50
TubesAluminium304001674.659 851RM 885.50
TubesAluminium304001634.659 847RM 885.50

Compare similar models

Dry Block Heater, 4 Block, analog, EU-Plug
Available soon
Ohaus Analog Dry Block Heater, 4 Block, EU Plug

RM 5,538.50

Inc. GST

Manufacturer P/N

30392068

Part Number

4.659 492

Manufacturer

OHAUS

Depth

429 mm

Dry Block Heater, 1 Block, analog, EU-Plug
Available soon
Ohaus Analog Dry Block Heater, 1 Block, EU Plug

RM 3,025.00

Inc. GST

Manufacturer P/N

30392047

Part Number

4.659 489

Manufacturer

OHAUS

Depth

315 mm

Dry Block Heater, 2 Block, analog, EU-Plug
Available soon
Ohaus Analog Dry Block Heater, 2 Block, EU Plug

RM 4,125.00

Inc. GST

Manufacturer P/N

30392054

Part Number

4.659 490

Manufacturer

OHAUS

Depth

391 mm

Dry Block Heater, 6 Block, analog, EU-Plug
Available soon
Ohaus Dry Block Heater, 6 Block, Analog, EU Plug

RM 7,986.00

Inc. GST

Manufacturer P/N

30392075

Part Number

4.659 493

Manufacturer

OHAUS

Depth

531 mm

Frequently asked questions

It is designed for precise and reliable heating in laboratory applications. This 4-block unit offers exceptional temperature stability and uniformity, making it ideal for processes such as enzyme reactions, incubation, and nucleic acid denaturation.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 5,538.50

Inc. GST