Representative Image

Nabertherm High Temperature Furnace LHTCT 03/16/C550 with Controller C550, SiC Rod Heated, Max 1550°C

Depth int.

Type of door

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. temperature

Max. voltage

Nominal capacity

Power supply

Rated capacity

Type

Weight

Specifications

Compare models
HS Code #
85141980
Depth int.
210 mm
Type of door
Lift door
Ext. dim. (WxDxH)
415 x 545 x 490 mm
Ext. depth
545 mm
Ext. height
490 mm
Ext. width
415 mm
Power supply frequency
50/60 Hz
Height int.
120 mm
Int. Dim. (WxDxH)
120 x 210 x 120 mm
Int. width
120 mm

RM 64,856.00

Inc. GST

Available soon

Product description

The Nabertherm High Temperature Furnace LHTCT 03/16/C550 is designed for high-temperature applications, featuring a SiC (Silicon Carbide) rod heating system. With a maximum temperature of 1550°C, this furnace is ideal for sintering, ceramics, metal testing, and other high-temperature processes. The furnace is equipped with the reliable C550 controller, providing precise temperature regulation and ease of operation. The furnace's advanced design ensures energy-efficient heating and uniform temperature distribution for accurate and consistent results.

Key Features:

  • Brand: Nabertherm
  • Model: LHTCT 03/16/C550
  • Maximum Temperature: 1550°C, ideal for high-temperature processes
  • Heating System: SiC rod heating for high efficiency and durability
  • Controller: Equipped with the C550 controller for precise and easy temperature control
  • Applications: Suitable for sintering, ceramics, metal testing, and other high-temperature processes
  • Energy Efficiency: Designed for energy-efficient operation without sacrificing performance
  • Uniform Heat Distribution: Ensures consistent heating for optimal results
  • Durable Construction: Built with high-quality materials for long-lasting reliability

The Nabertherm High Temperature Furnace LHTCT 03/16/C550 is the ideal solution for industries and laboratories requiring precise temperature control and uniform heating for high-temperature applications.

Downloads

Compare similar models

High temperature furnace LHTCT 03/16/C550 with controller C 550, SiC rod heated, max. 1550°C

Manufacturer P/N

LC034H6ON5

Part Number

9.764 587

Manufacturer

Nabertherm

Depth int.

210 mm

High temperature furnace LHTCT 01/16/C550 with controller C 550, SiC rod heated, max. 1550°C

Manufacturer P/N

LC014H6ON1

Part Number

9.764 586

Manufacturer

Nabertherm

Depth int.

120 mm

High-Temperature furnace LHTC 03/16/C550 with controller C 550, max. 1600°C SiC-rod heated, with flap door

Manufacturer P/N

LC034K6ON5

Part Number

6.235 199

Manufacturer

Nabertherm

Depth int.

210 mm

High temperature furnace LHTCT 08/16/C550 with controller C 550, SiC rod heated, max. 1550°C

Manufacturer P/N

LC084H6ON8

Part Number

9.764 588

Manufacturer

Nabertherm

Depth int.

290 mm

High temperature furnace LHTC 08/16/C550 with controller C 550, max. 1600°C SiC rod heated, with clap door

Manufacturer P/N

LC084K6ON8

Part Number

9.764 592

Manufacturer

Nabertherm

Depth int.

290 mm

Frequently asked questions

It is designed for high-temperature applications, featuring a SiC (Silicon Carbide) rod heating system. With a maximum temperature of 1550°C, this furnace is ideal for sintering, ceramics, metal testing, and other high-temperature processes. The furnace is equipped with the reliable C550 controller, providing precise temperature regulation and ease of operation. The furnace's advanced design ensures energy-efficient heating and uniform temperature distribution for accurate and consistent results.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story