Memmert Compressor Cooling Incubator ICP260, 256 L, -12 to +60°C

Brand:Memmert

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Nominal capacity

Plug type

Type

Weight

Specifications

Compare models
Cooling system
Cooling compressor
Depth int.
500 mm
Ext. dim. (WxDxH)
824 x 684 x 1,552 mm
Ext. depth
684 mm
Ext. height
1552 mm
Ext. width
824 mm
Power supply frequency
50/60 Hz
Height int.
800 mm
Int. Dim. (WxDxH)
640 x 500 x 800 mm
Int. width
640 mm

RM 60,610.00

Inc. GST

Available soon

Product description

The Memmert Compressor Cooling Incubator ICP260, 256 L, -12 to +60°C, is designed for precise temperature control in laboratory applications requiring reliable cooling and heating performance. Featuring the advanced ControlCOCKPIT interface, this incubator enables intuitive operation and supports rapid transitions between heating and cooling cycles, making it ideal for temperature-sensitive processes around and below ambient conditions.

Key Features:

  • Brand: Memmert
  • Type: Compressor cooling incubator
  • Model: ICP260
  • Capacity: 256 L
  • Temperature Range: -12 to +60°C
  • Control: PID microprocessor control with integrated auto-diagnostic system
  • Display: TwinDISPLAY ControlCOCKPIT with two TFT colour displays
  • Construction: Stainless steel interior, material 1.4301 (ASTM 304), for durability and easy cleaning
  • Housing: Structured stainless steel exterior with scratch-resistant finish and lockable castors
  • Data Logging: Integrated data logger with a storage capacity of at least 10 years
  • Functions: SetpointWAIT function for precise process timing and adjustment of three calibration values for temperature and additional parameters
  • Timer: Digital backwards counter with target time setting adjustable from 1 minute to 99 days
  • Languages: German, English, French, Spanish, Polish, Czech, and Hungarian language settings available
  • Application: Suitable for laboratory incubation, cooling, and temperature cycling processes
  • Packaging: Sold individually

This Memmert cooling incubator is a practical solution for laboratories requiring quiet operation, precise thermal control, and advanced programming capabilities for complex temperature applications.

Compare similar models

Compressor cooling incubator ICP260 256 ltr., -12...+60°C

Manufacturer P/N

ICP260

Part Number

9.538 015

Manufacturer

Memmert

Depth int.

500 mm

Compressor cooling incubator ICP110 108 ltr., -12...+60°C

Manufacturer P/N

ICP110

Part Number

9.538 014

Manufacturer

Memmert

Depth int.

400 mm

Compressor cooling incubator ICP450 449 ltr., -12...+60°C

Manufacturer P/N

ICP450

Part Number

9.538 016

Manufacturer

Memmert

Depth int.

600 mm

Compressor cooling incubator ICP750 749 ltr., -12...+60°C

Manufacturer P/N

ICP750

Part Number

9.538 017

Manufacturer

Memmert

Depth int.

600 mm

Compressor cooling incubator ICP110 UK 108 ltr., -12...+60°C

Manufacturer P/N

ICP110 UK

Part Number

6.263 156

Manufacturer

Memmert

Depth int.

400 mm

Frequently asked questions

It is designed for precise temperature control in laboratory applications requiring reliable cooling and heating performance. Featuring the advanced ControlCOCKPIT interface, this incubator enables intuitive operation and supports rapid transitions between heating and cooling cycles, making it ideal for temperature-sensitive processes around and below ambient conditions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 60,610.00

Inc. GST