Representative Image

Macherey-Nagel Capillary Column Optima 17, ID 0.32 mm, Film Thickness 0.25 µm, Length 50 m

Film thickness

Int. Ø

Length

Max. temperature programme

Temperature max. isotherm

Specifications

Compare models
Film thickness
0.25 µm
Int. Ø
0.32 mm
Length
50 m
Material column
Quartz glass
Max. temperature programme
340 °C
Polarity
Mid-polar
Temperature max. isotherm
320 °C
UNSPSC
41115710
USP listing
G3

RM 8,482.10

Inc. GST

Available soon

Product description

The Macherey-Nagel Capillary Column Optima 17 (ID 0.32 mm, Film Thickness 0.25 µm, Length 50 m) is a high-performance column designed for accurate and reliable gas chromatography. Ideal for a wide range of applications, it offers excellent separation efficiency, particularly for complex samples. The Optima 17 stationary phase is perfect for separating polar compounds, ensuring precise analytical results for food, environmental, and pharmaceutical industries.

Key Features:

  • Brand: Macherey-Nagel
  • Column Type: Capillary column for gas chromatography
  • Diameter: 0.32 mm
  • Film Thickness: 0.25 µm
  • Length: 50 m
  • Phase: Optima 17 stationary phase for polar compound separation
  • Application: Ideal for food, environmental, and pharmaceutical analysis

This reliable Macherey-Nagel capillary column is designed for high-resolution separations, ensuring exceptional chromatographic performance in complex analytical tasks.

Compare similar models

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726351.50

Part Number

4.003 114

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726022.30

Part Number

4.003 027

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726022.50

Part Number

4.003 028

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726067.30

Part Number

4.003 047

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726351.25

Part Number

4.003 112

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726067.60

Part Number

4.003 049

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m

Manufacturer P/N

726757.30

Part Number

4.003 195

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726351.30

Part Number

4.003 113

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.53 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726747.30

Part Number

4.003 192

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 60 m

Manufacturer P/N

726742.60

Part Number

4.003 184

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 25 m

Manufacturer P/N

726757.25

Part Number

4.003 194

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.15 µm length: 30 m

Manufacturer P/N

726755.30

Part Number

4.003 193

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726067.25

Part Number

4.003 046

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 30 m

Manufacturer P/N

726742.30

Part Number

4.003 182

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 25 m

Manufacturer P/N

726742.25

Part Number

4.003 181

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.10 mm, film thickness: 0.1 µm length: 10 m

Manufacturer P/N

726848.10

Part Number

4.003 236

Manufacturer

Macherey-Nagel

Film thickness

0.10 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726022.25

Part Number

4.003 026

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 50 m

Manufacturer P/N

726742.50

Part Number

4.003 183

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726022.60

Part Number

4.003 029

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726351.60

Part Number

4.003 115

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726744.60

Part Number

4.003 188

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726067.50

Part Number

4.003 048

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726744.25

Part Number

4.003 185

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726744.50

Part Number

4.003 187

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 50 m

Manufacturer P/N

726757.50

Part Number

4.003 196

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.53 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726747.25

Part Number

4.003 191

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 60 m

Manufacturer P/N

726757.60

Part Number

4.003 197

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726744.30

Part Number

4.003 186

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Frequently asked questions

It is a high-performance column designed for accurate and reliable gas chromatography. Ideal for a wide range of applications, it offers excellent separation efficiency, particularly for complex samples. The Optima 17 stationary phase is perfect for separating polar compounds, ensuring precise analytical results for food, environmental, and pharmaceutical industries.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 8,482.10

Inc. GST