Representative Image

LLG Labware Syringe Filters RC, 0.45 µm, Ø 13 mm Transparent Non-Sterile, Pack of 500

Membrane Ø

Pore size

Specifications

Compare models
HS Code #
39269097
Colour
Transparent
Connection inlet
Luer-Lock female
Connetion outlet
Luer-Slip male
Membrane Ø
13 mm
Feature
Hydrophilic
Material housing
PP
Material membrane
Regenerated cellulose (RC)
Pore size
0.45 µm
Sterile
No
UNSPSC
41104922

RM 3,925.62

Inc. GST

Supplier Stock: 1
Delivery: 2-4 weeks

Product description

LLG Labware's Syringe Filters with regenerated cellulose (RC) membranes are designed for efficient filtration of various aqueous and organic solutions. Featuring a pore size of 0.45 µm and a diameter of 13 mm, these transparent, non-sterile filters are ideal for applications in HPLC, pharmaceutical, environmental, biotechnology, as well as food and beverage testing laboratories. The RC membrane ensures excellent chemical compatibility and low protein binding, making it suitable for a wide range of laboratory filtrations.

Key Features:

  • Brand: LLG Labware
  • Membrane Material: Regenerated cellulose (RC) for broad chemical compatibility
  • Pore Size: 0.45 µm, suitable for fine particulate removal
  • Diameter: 13 mm, compact design for minimal sample loss
  • Housing: Transparent, non-sterile, made without adhesives to prevent sample contamination
  • Applications: Ideal for filtration of aqueous and organic solutions in various laboratory settings
  • Packaging: Pack of 500 filters for extended laboratory use

These syringe filters are essential for laboratories requiring reliable and efficient filtration solutions across diverse applications.

Compare similar models

LLG-Syringe filters, RC, 0,45 µm Ø 13 mm, transparent, non sterile, pack of 500

Manufacturer P/N

9055532

Part Number

9.055 532

Manufacturer

LLG Labware

Membrane Ø

13 mm

LLG-Syringe filters, RC, 0,45 µm Ø 25 mm, transparent, non sterile, pack of 500

Manufacturer P/N

9055533

Part Number

9.055 533

Manufacturer

LLG Labware

Membrane Ø

25 mm

LLG-Syringe filters, RC, 0.20 µm Ø 25 mm, transparent, non sterile, pack of 500

Manufacturer P/N

9055531

Part Number

9.055 531

Manufacturer

LLG Labware

Membrane Ø

25 mm

LLG-Syringe filters, RC, 0,22 µm Ø 13 mm, transparent, non sterile, pack of 500

Manufacturer P/N

9055530

Part Number

9.055 530

Manufacturer

LLG Labware

Membrane Ø

13 mm

More items to explore

LLG-Syringe filters PTFE, Polytetrafluorethylene

ProductMaterial housingMaterial membraneMfr#Part#AvailabilityPrice
PPPTFE62553316.255 331In stockRM 2,736.25
PPPTFE79704027.970 402In stockRM 3,588.75
PPPTFE90555359.055 535In stockRM 2,736.25
PPPTFE79703857.970 385In stockRM 3,588.75

LLG-Syringe filters PES, Polyethersulfone

ProductMaterial housingMaterial membraneMfr#Part#AvailabilityPrice
PPPES90555249.055 524RM 3,416.88
AcrylicPES62856956.285 695RM 708.12
AcrylicPES62857066.285 706RM 790.62
PPPES90555269.055 526RM 3,416.88
AcrylicPES62856966.285 696RM 708.12

Frequently asked questions

LLG Labware's Syringe Filters with regenerated cellulose (RC) membranes are designed for efficient filtration of various aqueous and organic solutions. Featuring a pore size of 0.45 µm and a diameter of 13 mm, these transparent, non-sterile filters are ideal for applications in HPLC, pharmaceutical, environmental, biotechnology, as well as food and beverage testing laboratories. The RC membrane ensures excellent chemical compatibility and low protein binding, making it suitable for a wide range of laboratory filtrations.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story