Representative Image

LAUDA Universa MAX U 40 M Heating thermostat 200-240 V; 50/60 Hz

Brand:Lauda

Bath depth

Depth opening

Opening (WxD)

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Max. delivery pressure

Max. volume bath

Min. temperature

Min. volume bath

Temperature

Type

Volume bath

Weight

Width opening

Specifications

Compare models
Bath depth
200 mm
Depth opening
600 mm
Opening (WxD)
300 x 600 mm
Ext. dim. (WxDxH)
380 x 850 x 499 mm
Ext. depth
850 mm
Ext. height
499 mm
Ext. width
380 mm
Power supply frequency
50/60 Hz
Heating capacity
3.7 kW
IP code
IP 21

RM 39,699.00

Inc. GST

Available soon

Product description

The heating thermostat with advanced electronics ensures precise control accuracy and uniform temperature distribution. It can be used for internal and external temperature control tasks. The innovative bath edge ventilation prevents icing and blocks condensate and vapours from entering the control head. The integrated web server allows flexible remote control within the company network via the LAUDA Command App or browser-based, secured by PKI and 2-factor authentication. The connection to LAUDA.LIVE enables cloud-based data analysis and remote maintenance.

  • Powerful pressure-suction pump with eight selectable performance levels

  • Front switch on the control head for adjusting the pump output during operation

  • Colour 5" TFT display with progression graph

  • Clear menu navigation in six languages and clear operating status icons

  • Integrated Ethernet and USB interface

  • Interface for an external Pt100 temperature probe

  • With programmer, safe mode, calibration options, controller self-adaptation, and weekly scheduler for process control

  • Effective over- and under-level protection

  • Adjustable overtemperature protection with acoustic alarm

  • Automatic system diagnostics at start-up with alarm and error message display

  • Smart temperature control media management with automatic limit value adjustment

  • Tmax button allows direct access to overtemperature protection setting

  • Insulated stainless steel bath with drain tap

  • Pump connection M16x1

  • Safety class III/FL

Compare similar models

LAUDA Universa MAX U 40 M Heating thermostat 200-240 V; 50/60 Hz

Manufacturer P/N

L004141

Part Number

4.713 300

Manufacturer

Lauda

Bath depth

200 mm

LAUDA Universa MAX U 8 M Heating thermostat, 200-240 V; 50/60 Hz

Manufacturer P/N

L004138

Part Number

4.713 314

Manufacturer

Lauda

Bath depth

200 mm

LAUDA Universa MAX U 20 M Heating thermostat, 200-240 V; 50/60 Hz

Manufacturer P/N

L004140

Part Number

4.713 293

Manufacturer

Lauda

Bath depth

320 mm

LAUDA Universa MAX U 12 M Heating thermostat, 200-240 V; 50/60 Hz

Manufacturer P/N

L004139

Part Number

4.713 276

Manufacturer

Lauda

Bath depth

200 mm

More items to explore

Heating thermostat Universa MAX, WLAN capable

ProductPlug typeTypeMfr#Part#AvailabilityPrice
CEEU 40 ML0037524.713 302RM 39,699.00
CEEU 12 ML0037504.713 278RM 36,575.00
CEEU 20 ML0037514.713 294RM 37,999.50
CEEU 8 ML0037494.713 316RM 34,611.50
CEEU 16 ML0038224.713 284RM 37,323.00

Heating thermostat with ball bearing Universa MAX

ProductPlug typeTypeMfr#Part#AvailabilityPrice
CEEU 40 ML0041504.713 301RM 43,092.50
CEEU 12 ML0041494.713 277RM 37,592.50
CEEU 8 ML0041484.713 315RM 35,629.00

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 39,699.00

Inc. GST