Representative Image

KGW Isotherm Cold Trap Type KF 29-K, Complete, with Dewar Flask, 12°C and Plastic Ring

Connection size

Type

Specifications

Compare models
HS Code #
70172000
Connection size
S 29
Material
Boro 3.3
Type
KF 29-K
UNSPSC
41103024
Volume condensate
150 ml
Volume coolant
1000 ml

RM 3,410.00

Inc. GST

Available soon

Product description

The KGW Isotherm Cold Trap Type KF 29-K is a precision-engineered cold trap designed for effective condensation and collection of vapours in laboratory environments. This complete set includes a Dewar flask type 12 C and a durable plastic ring for secure setup, ensuring consistent cooling performance and protection for vacuum systems. Built with high-quality materials, it delivers reliability and long service life in analytical and cryogenic applications.

Key Features:

  • Brand: KGW Isotherm
  • Model: KF 29-K
  • Temperature Range: Dewar flask rated for cryogenic applications (12 °C type)
  • Components: Includes Dewar flask and plastic ring for stability and ease of use
  • Application: Ideal for vapour condensation and cold trapping in laboratory setups
  • Connection Versions: S 29 = spherical ground joint S 29; O 29 = spherical ground joint S 29 with O-ring seal; GL 18 = glass thread GL 18 with PTFE olive Ø 10 mmScope of Supply: Cold trap; Support ring; Dewar flask type 12 C

Note: The standard assembly is designed for use with LN2 as coolant. When using CO2 and acetone, please order the CO2 wire basket separately.

The KGW Isotherm Cold Trap Type KF 29-K provides efficient condensation and dependable protection for vacuum systems, making it an indispensable component in laboratory and analytical cooling applications.

Compare similar models

Cold trap type KF 29-K complete with dewar flask 12 C and plastic ring

Manufacturer P/N

1731

Part Number

9.032 065

Manufacturer

KGW Isotherm

Connection size

S 29

Cold trap type KF 29-GL complete with dewar flask 12 C and plastic ring

Manufacturer P/N

1740

Part Number

9.032 067

Manufacturer

KGW Isotherm

Connection size

GL 18

Cold trap type KF 29-OK complete with dewar flask 12 C and plastic ring

Manufacturer P/N

1735

Part Number

9.032 066

Manufacturer

KGW Isotherm

Connection size

O 29

More items to explore

Cold traps with Dewar flask, borosilicate glass 3.3, one-piece, long version with spout

ProductTypeVolume condensateMfr#Part#AvailabilityPrice
KFL 29-GL-A250 ml173829.032 076RM 4,130.50
KFL 29-K-A250 ml173809.032 074RM 4,604.05
KFL 29-OK-A250 ml173819.032 075RM 4,640.35

Cold traps with Dewar flask, borosilicate glass 3.3, one-piece, standard version with spout

ProductTypeVolume condensateMfr#Part#AvailabilityPrice
KF 29-GL-A150 ml173729.032 073RM 3,718.00
KF 29-OK-A150 ml173719.032 072RM 4,343.90
KF 29-K-A150 ml173709.032 071RM 4,156.35

Frequently asked questions

It is a precision-engineered cold trap designed for effective condensation and collection of vapours in laboratory environments. This complete set includes a Dewar flask type 12 C and a durable plastic ring for secure setup, ensuring consistent cooling performance and protection for vacuum systems. Built with high-quality materials, it delivers reliability and long service life in analytical and cryogenic applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story