Representative Image

KEFO Waste SafetyCap (DIN60/61), With 5 x Standard Ports

Brand:KEFO

Capillary connections

No. of fittings

Thread

No. of olives

No. of blind plugs

Specifications

Compare models
Capillary connections
5
Material
PTFE
No. of blind plugs
4
No. of fittings
5 x 2,3 ... 3,2 mm, 4 x 1,6 mm
No. of olives
4 x 7 ... 9 mm
Thread
DIN 60/61
UNSPSC
41115700

RM 880.00

Inc. GST

Supplier Stock: 2
Delivery: 2-4 weeks

Product description

The KEFO Waste SafetyCap (DIN60/61), With 5 x Standard Ports is designed for collecting liquid HPLC waste while helping reduce exposure to hazardous solvent vapours. The activated carbon in the exhaust filter binds hazardous vapours, and replacement of the exhaust filter after 6 months is recommended. Both capillaries and hose barbs can be inserted into the capillary connections for flexible laboratory waste handling.

Key Features:

  • Brand: KEFO
  • Product Type: Waste SafetyCap
  • Connection: DIN60/61
  • Ports: 5 x standard ports
  • Application: Ideal for collecting liquid HPLC waste
  • Filter: Activated carbon exhaust filter binds hazardous solvent vapours
  • Replacement: Exhaust filter replacement recommended after 6 months
  • Compatibility: Capillaries and hose barbs can be inserted into the capillary connections
  • Materials: Caps and fittings made of PP, body and hose barbs made of PTFE
  • Special Features: With timestrip sticker
  • Note: Exhaust filter to be ordered separately

This KEFO Waste SafetyCap is suitable for laboratories requiring a secure cap solution for HPLC waste collection and solvent vapour management.

Accessories

Exhaust filters for Waste SafetyCaps

ProductShelf lifeThreadMfr#Part#AvailabilityPrice
3 monthsGL 14SC000131.2*LE4.684 241RM 649.00
6 monthsGL 14SC000132.2*LE4.684 242RM 1,067.00

Fittings for Eluent SafetyCaps / Waste SafetyCaps

ProductMaterialColourMfr#Part#AvailabilityPrice
PPBlueSC000140.1*LE4.684 223RM 418.00
PPGreenSC000139.10*LE4.684 221RM 418.00
PPPurpleSC000138.10*LE4.684 220RM 368.50

Compare similar models

Waste SafetyCap (DIN60/61) with 5x Standard ports

Manufacturer P/N

SC000149.1*LE

Part Number

4.684 236

Manufacturer

KEFO

Capillary connections

5

Waste SafetyCap (GL45/DIN45) with 3x Standard ports incl. 3xPP fitting

Manufacturer P/N

SC000129.1*LE

Part Number

4.684 227

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (GL45/DIN45) with 3x Standard ports iocl. 2xPP fitting+1xHoseBarb

Manufacturer P/N

SC000130.2*LE

Part Number

4.684 228

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (GL45/DIN45) with 2x Standard ports

Manufacturer P/N

SC000144.1*LE

Part Number

4.684 229

Manufacturer

KEFO

Capillary connections

2

Waste SafetyCap (S55/DIN51) with 3x Standard ports
Available soon
KEFO Waste SafetyCap (S55/DIN51), with 3x Standard ports

RM 726.00

Inc. GST

Manufacturer P/N

SC000137.1*LE

Part Number

4.684 230

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (S55/DIN51) with 4x Standard ports
Available soon
KEFO Waste SafetyCap (S55/DIN51), with 4x Standard ports

RM 594.00

Inc. GST

Manufacturer P/N

SC000145.1*LE

Part Number

4.684 231

Manufacturer

KEFO

Capillary connections

4

Waste SafetyCap (DIN60/61) with 3x Standard ports
Available soon
KEFO Waste SafetyCap (DIN60/61), with 3x Standard ports

RM 753.50

Inc. GST

Manufacturer P/N

SC000147.1*LE

Part Number

4.684 234

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (DIN60/61) with 4x Standard ports
Available soon
KEFO Waste SafetyCap (DIN60/61), with 4x Standard ports

RM 753.50

Inc. GST

Manufacturer P/N

SC000148.1*LE

Part Number

4.684 235

Manufacturer

KEFO

Capillary connections

4

Frequently asked questions

It is designed for collecting liquid HPLC waste while helping reduce exposure to hazardous solvent vapours. The activated carbon in the exhaust filter binds hazardous vapours, and replacement of the exhaust filter after 6 months is recommended. Both capillaries and hose barbs can be inserted into the capillary connections for flexible laboratory waste handling.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 880.00

Inc. GST