Brand:IKA

Max. voltage

Min. voltage

Plug type

Power supply

Type

Specifications

Compare models
HS Code #
84798200
Depth
106 mm
Dimensions (WxDxH)
87 x 106 x 271 mm
Display
Digital
Power supply frequency
50/60 Hz
Height
271 mm
IP code
IP 20
Max. speed
25000 1/min
Max. Viscosity
5000 mPa·s
Max. voltage
240 V
Max. working volume
1500 ml

RM 11,528.00

Inc. GST

Available soon

Product description

The IKA ULTRA-TURRAX T 18 Digital S 2 Disperser is a powerful, high-performance laboratory tool designed for efficient mixing, dispersing, and homogenizing applications. With a digital control system, it offers precise speed control and a smooth operation for laboratory processes requiring high shear forces. Featuring a UK plug (230 V, 50/60 Hz), it is ready for use in standard UK electrical setups.

Key Features:

  • Brand: IKA
  • Speed Range: Digital speed control for consistent and reproducible results
  • Plug Type: UK plug, suitable for 230 V, 50/60 Hz electrical systems
  • Applications: Ideal for dispersing, homogenizing, and emulsifying liquids in various laboratory experiments
  • Built for Precision: High shear dispersing capabilities for efficient processing of samples, including tough and viscous materials
  • Reliable Performance: Designed for continuous operation, ensuring durability and effective results over time
  • Note: Dispersing heads must be ordered separately.

Scope of Supply:

  • Homogeniser

The IKA ULTRA-TURRAX T 18 Digital S 2 Disperser is perfect for laboratories requiring high precision and effective dispersion of samples. With its digital control system and robust performance, it meets the needs of both routine and advanced laboratory tasks.

Downloads

Accessories

Plate stands for overhead stirrers and Dispersers T 18 and T 25

ProductTypeDepthMfr#Part#AvailabilityPrice
R 1826316 mm00031601009.224 032In stockRM 2,750.00
R 1825316 mm00031600009.224 031RM 2,491.50
R 1827316 mm00031602009.224 033RM 2,931.50

Bossheads R 182 for overhead stirrers and Dispersers T 18 and T 25

ProductTypeUNSPSCMfr#Part#AvailabilityPrice
R 1824112241300026577009.224 292In stockRM 957.00

Compare similar models

ULTRA-TURRAX® T 18 digital S 2 Disperser, with UK plug 230 V, 50/60 Hz

Manufacturer P/N

0003720002

Part Number

9.570 944

Manufacturer

IKA

Max. voltage

240 V

ULTRA-TURRAX® T 18 digital Disperser, 230 V, 50/60 Hz
Available soon
IKA ULTRA-TURRAX T 18 Digital, Disperser, 230 V, 50/60 Hz

RM 11,495.00

Inc. GST

Manufacturer P/N

0003720000

Part Number

9.570 943

Manufacturer

IKA

Max. voltage

240 V

ULTRA-TURRAX® T 18 digital S 3 Disperser, with Swiss plug 230 V, 50/60 Hz

Manufacturer P/N

0003720003

Part Number

9.570 945

Manufacturer

IKA

Max. voltage

240 V

ULTRA-TURRAX® T 18 digital S 1 Disperser, with US plug 100-120V 50/60Hz

Manufacturer P/N

0003720001

Part Number

6.313 100

Manufacturer

IKA

Max. voltage

120 V

Frequently asked questions

It is a powerful, high-performance laboratory tool designed for efficient mixing, dispersing, and homogenizing applications. With a digital control system, it offers precise speed control and a smooth operation for laboratory processes requiring high shear forces. Featuring a UK plug (230 V, 50/60 Hz), it is ready for use in standard UK electrical setups.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story