Representative Image

IKA Magnetic Stirrer RCT Digital with Heating, 230V 50/60Hz

Brand:IKA

Plug type

Specifications

Compare models
Control accuracy heating temperature
±5 °C
Depth
270 mm
Dimensions (WxDxH)
160 x 270 x 85 mm
Display
Digital
Power supply frequency
50/60 Hz
Heating capacity
600 W
Heating temperature
10 ... 310 °C
Height
85 mm
IP code
IP 42
Material housing
Glass

RM 8,118.00

Inc. GST

Supplier Stock: 3
Delivery: 2-4 weeks

Product description

The IKA Magnetic Stirrer RCT Digital with Heating (230V, 50/60Hz) is a high-performance laboratory device engineered for precise stirring and controlled heating of liquids. Featuring a chemically resistant glass housing and an aluminium heating plate, it ensures efficient heat transfer and easy cleaning. The advanced digital control system allows accurate adjustment of stirring speed and temperature, supporting sensitive reaction kinetics with integrated timer and counter functions.

Key Features:

  • Brand: IKA
  • Functionality: Magnetic stirring combined with integrated heating in a compact unit
  • Heating Capacity: Aluminium heating plate delivers efficient and precise temperature control up to 360 °C
  • Digital Control: Intuitive LCD display with adjustable stirring direction, timer, and counter
  • Surface: Glass housing for excellent chemical resistance and easy cleaning
  • Temperature Sensor: PT1000 sensor enables direct medium temperature monitoring
  • Safety Features: Adjustable safety circuit and IKA SmartTemp® hot surface warning to prevent burn injuries
  • Connectivity: USB/RS232 interface for firmware updates and data management
  • Voltage: 230V, 50/60Hz for reliable laboratory operation
  • Warranty: 10 years
  • Applications: Ideal for chemical laboratories, research, and educational institutions

Scope of supply: Magnetic stirrer including PT1000 temperature sensor

The IKA Magnetic Stirrer RCT Digital with Heating combines precision stirring and reliable temperature control, making it an indispensable tool for laboratory environments requiring efficiency and accuracy.

Downloads

Accessories

Protective cover H 105

ProductTypeDescriptionMfr#Part#AvailabilityPrice
H 105Protective cover00250081364.684 040In stockRM 286.00

Compare similar models

Magnetic stirrer RCT digital with heating, 230V, 50 / 60Hz

Manufacturer P/N

0025004601

Part Number

6.286 692

Manufacturer

IKA

Plug type

EU

Magnetic stirrer RCT digital S 1 with heating, 115V, 50 / 60Hz US plug

Manufacturer P/N

0025004735

Part Number

6.327 592

Manufacturer

IKA

Plug type

US

Magnetic stirrer RCT digital S 2 with heating, 230V, 50 / 60Hz with UK plug

Manufacturer P/N

0025005221

Part Number

6.322 739

Manufacturer

IKA

Plug type

UK

Magnetic stirrer IKA Plate (RCT digital) with heating CH plug

Manufacturer P/N

0025005223

Part Number

4.715 712

Manufacturer

IKA

Plug type

CH

More items to explore

Magnetic stirrer RCT 5 digital

ProductPlug typeTypeMfr#Part#AvailabilityPrice
UKRCT 5 digital00200090954.715 631RM 8,321.50
CHRCT 5 digital00200090974.715 713RM 8,321.50

Frequently asked questions

It is a high-performance laboratory device engineered for precise stirring and controlled heating of liquids. Featuring a chemically resistant glass housing and an aluminium heating plate, it ensures efficient heat transfer and easy cleaning. The advanced digital control system allows accurate adjustment of stirring speed and temperature, supporting sensitive reaction kinetics with integrated timer and counter functions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 8,118.00

Inc. GST