Representative Image

IKA Hotplate C-MAG HP 10 S 2, IKATHERM, Glass Ceramics with UK Plug

Brand:IKA

Depth heating area

Depth

Heating area (WxD)

Dimensions (WxDxH)

Heating capacity

Max. voltage

Plug type

Power supply

Type

Weight

Width heating area

Width

Specifications

Compare models
Colour housing
Blue
Depth heating area
260 mm
Depth
415 mm
Heating area (WxD)
260 x 260 mm
Dimensions (WxDxH)
300 x 415 x 105 mm
Display
Digital
Power supply frequency
50/60 Hz
Heating capacity
1500 W
Height
105 mm
IP code
IP 21

Alternative in-stock items

RM 6,875.00

Inc. GST

Available soon

Product description

The IKA Hotplate C-MAG HP 10 S 2 IKATHERM is designed for efficient and reliable heating in laboratory environments. Featuring a durable glass ceramics surface, this hotplate ensures uniform heating, and its IKATHERM technology enhances temperature control for precise results. The unit comes with a UK plug for easy setup and use in the UK and compatible regions.

Key Features:

  • Brand: IKA
  • Model: C-MAG HP 10 S 2
  • Surface Material: Glass ceramics for durability and even heating
  • Technology: IKATHERM for precise temperature control
  • Plug Type: UK plug for regional compatibility
  • Application: Ideal for laboratory heating and mixing tasks

The IKA Hotplate C-MAG HP 10 S 2 IKATHERM is a high-performance solution for laboratories requiring efficient and reliable heating technology.

Downloads

Accessories

Electronic Contact thermometer ETS-D5

ProductTypeMax. temperatureMfr#Part#AvailabilityPrice
ETS-D5450 °C00033780009.720 241RM 3,415.50

Compare similar models

Hotplate C-MAG HP 10 S 2 IKATHERM®, glass ceramics with UK plug

Manufacturer P/N

0003582002

Part Number

4.008 100

Manufacturer

IKA

Depth heating area

260 mm

Hotplate C-MAG HP 7 IKATHERM®, glass ceramics
In stock
IKA Hotplate C-MAG HP 7, IKATHERM, Glass Ceramics

RM 5,038.00

Inc. GST

Manufacturer P/N

0003581800

Part Number

9.720 497

Manufacturer

IKA

Depth heating area

180 mm

Hotplate C-MAG HP 10 IKATHERM®, glass ceramics
In stock
IKA Hotplate C-MAG HP 10 IKATHERM, Glass/Ceramics

RM 6,875.00

Inc. GST

Manufacturer P/N

0003582000

Part Number

9.720 498

Manufacturer

IKA

Depth heating area

260 mm

Hotplate C-MAG HP 7 S 3 IKATHERM®, glass ceramics with Swiss plug

Manufacturer P/N

0003581803

Part Number

4.008 099

Manufacturer

IKA

Depth heating area

180 mm

Hotplate C-MAG HP 10 S 3 IKATHERM®, glass ceramics with Swiss plug

Manufacturer P/N

0003582003

Part Number

4.008 101

Manufacturer

IKA

Depth heating area

260 mm

Hotplate C-MAG HP 7 S 2 IKATHERM®, glass ceramics with UK plug

Manufacturer P/N

0003581802

Part Number

4.008 098

Manufacturer

IKA

Depth heating area

180 mm

Hotplate C-MAG HP 7 S 1 IKATHERM®, glass ceramics 115 V
Available soon
Hotplate C-MAG HP 7 S 1 IKATHERM®, glass ceramics 115 V

RM 5,038.00

Inc. GST

Manufacturer P/N

0003581801

Part Number

4.008 097

Manufacturer

IKA

Depth heating area

180 mm

Frequently asked questions

It is designed for efficient and reliable heating in laboratory environments. Featuring a durable glass ceramics surface, this hotplate ensures uniform heating, and its IKATHERM technology enhances temperature control for precise results. The unit comes with a UK plug for easy setup and use in the UK and compatible regions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 6,875.00

Inc. GST