Representative Image

Heidolph Scientific Hei-VAP Ultimate Control ml G6 CH-plug

Brand:Heidolph

Glassware

Plug type

Temperature

Type

Specifications

Compare models
Condenser
Vertical
Cooling surface
1400 cm²
Glassware
Without coating
Lift
Electrical
Max. speed
280 1/min
Max. temperature
210 °C
Max. voltage
230 V
Max. volume bath
4.5 l
Min. speed
10 1/min
Plug type
CH

RM 49,918.00

Inc. GST

Available soon

Product description

The Heidolph Scientific Hei-VAP Ultimate Control ml G6 CH-plug is a laboratory flask designed for laboratory sample handling and preparation. This devices are central control units for regulation of all process parameter: vacuum, cooling temperature, rotation and heating bath temperature.

Key Features:

  • Brand: Heidolph Scientific
  • Temperature range: This devices are central control units for regulation of all process parameter: vacuum, cooling temperature, rotation and heating bath temperature; 7'' touch display for controlling the entire system including the vacuum and the cooling temperature.
  • Design and operation: Available as hand or motor lift; separate knobs for quick access: the right one for direct vacuum control, the left one for the rotation; user defined evaporation processes (ramps) can be defined and saved; automatic evaporation with the Dynamic AUTOaccurate Program (DAA).
  • Display and interface: For precise monitoring, the pictogram on the-display also symbolizes active functions; setting of values either via the touch display or the separate quick access knobs; direct access to two favourites on the start screen.
  • Chemical resistance: Expandable solvent library: user defined favourites can be transfered to other devices using a USB stick.
  • Power and battery: USB, Micro SD and LAN-/RS 232 interfaces (Lab 4.0-ready).
  • Application: Suitable for laboratory sample handling and preparation.

Scope of Supply: Flask clamp Easy-Clip, vapour tube, ventilation cap, heating bath, 1-l receiving flask, 1-l evaporating flask, Control-Box

The Heidolph Scientific Hei-VAP Ultimate Control ml G6 CH-plug is a reliable glassware choice for laboratory environments that require documented specification and consistent performance.

Compare similar models

Hei-VAP Ultimate Control ML G6 CH-plug
Available soon
Heidolph Scientific Hei-VAP Ultimate Control ml G6 CH-plug

RM 49,918.00

Inc. GST

Manufacturer P/N

576-02600-04

Part Number

4.703 486

Manufacturer

Heidolph

Glassware

Without coating

Rotary evapor. Hei-VAP Ultimate Control ML/G6B with motor lift, plastic-coated glass sets

Manufacturer P/N

576-02610-00

Part Number

4.669 051

Manufacturer

Heidolph

Glassware

Coated

Rotary evapor. Hei-VAP Ultimate Control ML/G6 with motor lift

Manufacturer P/N

576-02600-00

Part Number

4.669 046

Manufacturer

Heidolph

Glassware

Without coating

Hei-VAP Ultimate Control ML G6 UK-plug
Available soon
Heidolph Scientific Hei-VAP Ultimate Control ml G6 UK-plug

RM 49,918.00

Inc. GST

Manufacturer P/N

576-02600-03

Part Number

4.703 485

Manufacturer

Heidolph

Glassware

Without coating

Hei-VAP Ultimate Control ML G6B CH-plug
Available soon
Heidolph Scientific Hei-VAP Ultimate Control ml G6B CH-plug

RM 51,991.50

Inc. GST

Manufacturer P/N

576-02610-04

Part Number

4.703 488

Manufacturer

Heidolph

Glassware

Coated

Hei-VAP Ultimate Control ML G6B UK-plug
Available soon
Heidolph Scientific Hei-VAP Ultimate Control ml G6B UK-plug

RM 51,991.50

Inc. GST

Manufacturer P/N

576-02610-03

Part Number

4.703 487

Manufacturer

Heidolph

Glassware

Coated

Frequently asked questions

It is a laboratory flask designed for laboratory sample handling and preparation. This devices are central control units for regulation of all process parameter: vacuum, cooling temperature, rotation and heating bath temperature.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 49,918.00

Inc. GST