Representative Image

Haldenwanger Crucible Lid, Ø 43 mm, Alsint

Crucible Ø

Lid Ø

Specifications

Compare models
Crucible Ø
41 mm
Lid Ø
45 mm
Material
Alsint
Standard
DIN 12904
UNSPSC
41121800

RM 484.00

Inc. GST

Available soon

Product description

The Haldenwanger Crucible Lid, Ø 43 mm, Alsint, Suitable For Crucible 9.250 402, 38 mm Ø, 9.250 414, 40 mm Ø, 9.250 390, 41 mm Ø is designed as a compatible lid for laboratory crucible applications. Made from Alsint, this crucible lid provides reliable coverage for compatible 38 mm Ø, 40 mm Ø, and 41 mm Ø crucibles in laboratory workflows.

Key Features:

  • Brand: Haldenwanger
  • Product Type: Crucible lid
  • Material: Alsint
  • Lid Diameter: Ø 43 mm
  • Compatibility: Suitable for crucibles 9.250 402, 9.250 414, and 9.250 390
  • Crucible Size: 38 mm Ø, 40 mm Ø, and 41 mm Ø
  • Application: Suitable for laboratory crucible use

This Haldenwanger Alsint crucible lid is suitable for laboratories requiring a compatible lid for selected 38 mm Ø, 40 mm Ø, and 41 mm Ø crucibles.

Compare similar models

Crucible lid Ø 43 mm, Alsint suitable to crucible 9.250 402 - 38 mm Ø 9.250 414 - 40 mm Ø, 9.250 390 - 41 mm Ø
Available soon
Haldenwanger Crucible Lid, Ø 43 mm, Alsint

RM 484.00

Inc. GST

Manufacturer P/N

79 D/7A/AL7

Part Number

6.304 147

Manufacturer

Haldenwanger

Crucible Ø

41 mm

Crucible lid Ø 87 mm, Alsint suitable to crucible 9.250 407 - 85 mm Ø, 9.250 418 - 85 mm Ø
Available soon
Haldenwanger Crucible Lid, Ø 87 mm, Alsint

RM 858.00

Inc. GST

Manufacturer P/N

79 D/1/AL7

Part Number

6.253 443

Manufacturer

Haldenwanger

Crucible Ø

85 mm

Crucible lid Ø 32 mm, Alsint suitable to crucible 9.250 400 - 30 mm Ø, 9.250 412 - 30 mm Ø, 9.250 389 - 30 mm Ø
Available soon
Haldenwanger Crucible Lid, Ø 32 mm, Alsint

RM 352.00

Inc. GST

Manufacturer P/N

79 D/8/AL7

Part Number

6.801 239

Manufacturer

Haldenwanger

Crucible Ø

30 mm

Crucible lid Ø 77 mm, Alsint suitable to crucible 9.250 405 - 62 mm Ø, 9.250 416 - 65 mm Ø, 9.250 394 - 66 mm Ø

Manufacturer P/N

79 D/3/AL7

Part Number

7.620 719

Manufacturer

Haldenwanger

Crucible Ø

66 mm

Crucible lid Ø 28 mm, Alsint suitable to crucible 9.250 411 - Ø 20 mm

Manufacturer P/N

79 D/9/AL7

Part Number

6.241 895

Manufacturer

Haldenwanger

Crucible Ø

20 mm

Crucible lid Ø 35 mm, Alsint suitable to crucible 9.250 401 - 33 mm Ø, 9.250 413 - 35 mm Ø

Manufacturer P/N

79 D/7/AL7

Part Number

7.602 538

Manufacturer

Haldenwanger

Crucible Ø

33 mm

Crucible lid Ø 64 mm, Alsint suitable to crucible 9.250 392 - 54 mm Ø, 9.250 393 - 60 mm Ø

Manufacturer P/N

79 D/4/AL7

Part Number

7.970 090

Manufacturer

Haldenwanger

Crucible Ø

60 mm

Crucible lid Ø 52 mm, Alsint suitable to crucible 9.250 404 - 50 mm Ø, 9.250 415 - 50 mm Ø, 9.250 391 - 48 mm Ø
Available soon
Haldenwanger Crucible Lid, Ø 52 mm, Alsint

RM 698.50

Inc. GST

Manufacturer P/N

79 D/5/AL7

Part Number

6.236 618

Manufacturer

Haldenwanger

Crucible Ø

50 mm

Crucible lid Ø 46 mm, Alsint suitable to crucible 9.250 403 - Ø 42 mm

Manufacturer P/N

79 D/6/AL7

Part Number

6.900 118

Manufacturer

Haldenwanger

Crucible Ø

42 mm

Crucible lid Ø 75 mm, Alsint suitable to crucible 9.250 406 - 73 mm Ø
Available soon
Haldenwanger Crucible Lid, Ø 75 mm Alsint

RM 946.00

Inc. GST

Manufacturer P/N

79 D/2/AL7

Part Number

6.231 115

Manufacturer

Haldenwanger

Crucible Ø

73 mm

Frequently asked questions

It is designed as a compatible lid for laboratory crucible applications. Made from Alsint, this crucible lid provides reliable coverage for compatible 38 mm Ø, 40 mm Ø, and 41 mm Ø crucibles in laboratory workflows.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 484.00

Inc. GST