Representative Image

Eppendorf Fixed-Angle Rotor F-35-48-17, with 24 Steel Sockets and Adapter for 24 x 15 mL Vials

Brand:Eppendorf

Specifications

For devices
5804/5804 R, 5810/5810 R, 5811 R
Max. rcf
5005 x g
Max. speed
5500 1/min
Type
F-35-48-17
UNSPSC
41103909

RM 5,643.00

Inc. GST

Available soon

Product description

The Eppendorf Fixed-Angle Rotor F-35-48-17 is designed for efficient and high-throughput centrifugation of 15 mL conical tubes. Compatible with Eppendorf centrifuge models 5804, 5804 R, 5810, and 5810 R, this rotor enhances sample processing capabilities in laboratory applications.

Key Features:

  • Brand: Eppendorf
  • Rotor Type: Fixed-Angle Rotor F-35-48-17
  • Capacity: Accommodates up to 24 x 15 mL conical tubes
  • Included Accessories: Comes with 24 steel sleeves for 15 mL tubes and adapters for 7.5/12 mL tubes
  • Maximum Speed: Up to 5,500 rpm
  • Maximum Relative Centrifugal Force (RCF): 5,005 x g
  • Rotor Radius: 14.8 cm
  • Compatibility: Suitable for Eppendorf centrifuge models 5804, 5804 R, 5810, and 5810 R
  • Autoclavable Components: Rotor, sleeves, adapters, and lids can be autoclaved at 121 °C for 20 minutes

Optimize your laboratory's centrifugation capabilities with the Eppendorf F-35-48-17 rotor, designed for efficient processing of 15 mL conical tubes. Ensure compatibility with your existing Eppendorf centrifuge models and enhance throughput with this high-capacity rotor system.



Frequently Asked Questions

1. What is the Eppendorf Fixed-Angle Rotor F-35-48-17, with 24 Steel Sockets and Adapter for 24 x 15 mL Vials used for?

It is designed for efficient and high-throughput centrifugation of 15 mL conical tubes. Compatible with Eppendorf centrifuge models 5804, 5804 R, 5810, and 5810 R, this rotor enhances sample processing capabilities in laboratory applications.

2. Is this product suitable for efficient and high-throughput centrifugation of 15 mL conical tubes?

Yes. It is designed for efficient and high-throughput centrifugation of 15 mL conical tubes, and offers a maximum speed of up to 5,500 rpm and a maximum relative centrifugal force (RCF) of 5,005 x g to support this kind of work.

3. What maximum speed and maximum relative centrifugal force (RCF) does this product have?

It has a maximum speed of up to 5,500 rpm, a maximum relative centrifugal force (RCF) of 5,005 x g and a rotor radius of 14.8 cm.

4. What is this product compatible with?

It is compatible with eppendorf centrifuge models 5804, 5804 R, 5810, and 5810 R. It also offers fixed-Angle Rotor F-35-48-17 and accommodates up to 24 x 15 mL conical tubes.

Downloads

Accessories

Steel sleeves and adapters for fixed angle rotor F-35-48-17

ProductForUNSPSCMfr#Part#AvailabilityPrice
F-35-48-174110391358207740029.776 900RM 2,574.00

Compare similar models

Constant angle rotor F-35-48-17 incl.24 steel sockets and adapter for 24x15ml vials

Manufacturer P/N

5820771003

Part Number

9.776 885

Manufacturer

Eppendorf

Constant angle rotor F-35-48-17 incl.48 steel sockets and adapter for 48x15ml vials

Manufacturer P/N

5820772000

Part Number

9.776 886

Manufacturer

Eppendorf

More items to explore

Fixed angle rotors for centrifuges 5804/5804 R, 5810/5810 R, 5811 R, incl. QuickLock® rotor lid

ProductTypeType of lidMfr#Part#AvailabilityPrice
FA-45-6-30Aerosol-tight58207150066.253 484RM 18,144.50
FA-45-48-11Aerosol-tight58207600019.776 879RM 10,917.50
FA-45-20-17Aerosol-tight58207650039.776 929RM 10,917.50

Frequently asked questions

It is designed for efficient and high-throughput centrifugation of 15 mL conical tubes. Compatible with Eppendorf centrifuge models 5804, 5804 R, 5810, and 5810 R, this rotor enhances sample processing capabilities in laboratory applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 5,643.00

Inc. GST