Representative Image

Eppendorf Centrifuge 5427 RN, 230 V/50-60 Hz

Brand:Eppendorf

Plug type

Specifications

Compare models
Depth
540 mm
Dimensions (WxDxH)
319 x 540 x 254 mm
Power supply frequency
50/60 Hz
Height
254 mm
Max. rcf
25001 x g
Max. speed
16220 1/min
Max. temperature
40 °C
Max. voltage
230 V
Min. speed
100 1/min
Min. temperature
-11 °C

Alternative in-stock items

RM 47,646.50

Inc. GST

Available soon

Product description

The Eppendorf Centrifuge 5427 RN, 230 V/50-60 Hz is a high-performance laboratory centrifuge designed for precise and reliable sample processing. With its compact size and powerful motor, this centrifuge is ideal for routine applications in molecular biology and cell culture. It offers exceptional speed and efficiency, ensuring fast separation of samples. The Eppendorf Centrifuge 5427 RN is equipped with a refrigeration system that allows temperature-sensitive samples to be processed safely. Its versatile rotor options make it suitable for a variety of sample types.

Key Features:

  • Brand: Eppendorf
  • Model: Centrifuge 5427 RN
  • Voltage: 230 V
  • Frequency: 50-60 Hz
  • Cooling: Refrigerated for temperature-sensitive samples
  • Capacity: Versatile rotor options for various sample types
  • Application: Ideal for routine molecular biology and cell culture applications

The Eppendorf Centrifuge 5427 RN is a reliable solution for laboratories requiring high-performance, efficient sample processing, and secure handling of temperature-sensitive materials.

Downloads

Accessories

Fixed angle rotors for Centrifuge 5427 R, incl. QuickLock® rotor lid

ProductTypeType of lidMfr#Part#AvailabilityPrice
FA-45-24-11-KitAerosol-tight54097040019.776 788RM 6,594.50
FA-45-24-11Aerosol-tight54097020099.776 785RM 5,560.50
FA-45-48-11Aerosol-tight54097100019.776 787RM 5,989.50
FA-45-30-11Aerosol-tight54097060049.776 786RM 5,131.50
FA-45-12-17Aerosol-tight54097000069.776 920RM 6,880.50

Swing-out rotor S-24-11-AT for centrifuge 5427 R

ProductTypeType of lidMfr#Part#AvailabilityPrice
S-24-11-ATAerosol-tight54097150039.776 792RM 9,388.50

Compare similar models

Centrifuge 5427 RN 230 V/50-60 Hz
Available soon
Eppendorf Centrifuge 5427 RN, 230 V/50-60 Hz

RM 47,646.50

Inc. GST

Manufacturer P/N

5429000015

Part Number

4.688 118

Manufacturer

Eppendorf

Plug type

EU

Centrifuge 5427 R, refrigerated 230V/50-60Hz, UK plug

Manufacturer P/N

5429000065

Part Number

4.700 724

Manufacturer

Eppendorf

Plug type

UK

Centrifuge 5427 R 230V/50-60Hz CH
Available soon
Eppendorf, Centrifuge 5427 R 230 V/50-60 Hz CH

RM 47,646.50

Inc. GST

Manufacturer P/N

5429000074

Part Number

4.721 146

Manufacturer

Eppendorf

Plug type

CH

More items to explore

Microcentrifuge 5427 R (General Lab Product), without rotor

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU5427 R54290000104.688 117RM 47,844.50
UK5427 R54290000604.700 728RM 45,386.00

Microcentrifuge 5427 R (IVD), with rotor FA-45-48-11

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU5427 R (IVD)54290002154.688 120In stockRM 51,067.50
CH5427 R (IVD)54290002774.721 147RM 51,073.00
UK5427 R (IVD)54290002654.700 725RM 51,067.50

Frequently asked questions

It is a high-performance laboratory centrifuge designed for precise and reliable sample processing. With its compact size and powerful motor, this centrifuge is ideal for routine applications in molecular biology and cell culture. It offers exceptional speed and efficiency, ensuring fast separation of samples. The Eppendorf Centrifuge 5427 RN is equipped with a refrigeration system that allows temperature-sensitive samples to be processed safely. Its versatile rotor options make it suitable for a variety of sample types.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 47,646.50

Inc. GST