Representative Image

Eppendorf CENT 5430, Keyp., 30 × 2 mL CH

Brand:Eppendorf

Depth

Dimensions (WxDxH)

Height

Plug type

Rated capacity

Type

Weight

Width

With cooling

Specifications

Compare models
Depth
420 mm
Dimensions (WxDxH)
340 x 420 x 250 mm
Power supply frequency
50/60 Hz
Height
250 mm
Max. rcf
25000 x g
Max. speed
15350 1/min
Max. voltage
230 V
Min. speed
100 1/min
Plug type
CH
Power supply
230 V, 50/60 Hz

RM 31,905.50

Inc. GST

Available soon

Product description

The Eppendorf centrifuge is designed for centrifugation of the supported laboratory vessels. It helps laboratories separate and process samples efficiently during routine preparation and analytical workflows. Its purpose-focused design helps users choose an appropriate product for their method and working environment.

Key Features:

  • Brand: Eppendorf
  • Product Type: Centrifuge
  • Application: Centrifugation of the supported laboratory vessels
  • Temperature Range: -11°C to +40°C
  • Capacity: 2 mL
  • Plug Type: CH plug
  • Configuration: Choice of 8 different rotors, e.g. MTP rotor, Falcon rotor for max. versatility
  • Relative Centrifugal Force: 30,130 × g
  • Automation: Automatic rotor recognition

Eppendorf CENT 5430, Keyp., 30 × 2 mL CH is a practical choice when centrifuge performance must match a clearly defined application. Its stated temperature range, capacity and plug type identify the important selection criteria. Together, these details support consistent handling and dependable use within the stated operating requirements.

Frequently Asked Questions

1. What is the Eppendorf CENT 5430, Keyp., 30 × 2 mL CH used for?

Eppendorf CENT 5430, Keyp., 30 × 2 mL CH is a centrifuge used for centrifugation of the supported laboratory vessels. It provides the specified product configuration for the stated laboratory, production or equipment-support task. The selected variant should be checked against the intended method or system before use.

2. Is this product suitable for centrifugation of the supported laboratory vessels?

Yes. It is designed for centrifugation of the supported laboratory vessels and supports the intended laboratory workflow. Users should confirm that the chosen configuration matches their method, equipment and working conditions before use.

3. What temperature range does this product support, and what capacity does it provide?

It supports a temperature range of -11°C to +40°C. It provides a capacity of 2 mL. These details help users confirm that the selected product matches the intended method and equipment setup.

4. What relative centrifugal force does it provide, and how is this product configured?

It provides a relative centrifugal force of 30,130 × g. It supports choice of 8 different rotors, e.g. MTP rotor, Falcon rotor for max. versatility. These details help users confirm that the selected product matches the intended method and equipment setup.

Accessories

Fixed angle rotors for microcentrifuges 5430/5430 R, incl. QuickLock® rotor lid

ProductTypeType of lidMfr#Part#AvailabilityPrice
FA-45-30-11Aerosol-tight54277530019.776 776RM 5,131.50
FA-45-16-17Aerosol-tight54277500029.776 923RM 6,880.50
FA-45-48-11Aerosol-tight54277540089.776 777RM 5,989.50
FA-45-24-11-KitAerosol-tight54277520059.776 775RM 6,594.50

Fixed angle rotors for microcentrifuges 5430/5430 R, incl. rotor lid

ProductTypeType of lidMfr#Part#AvailabilityPrice
F-45-64-5-PCRWith54277140069.776 745RM 6,286.50
F-45-48-11With54277550049.776 778RM 4,339.50
F-45-18-17-CryoWith54277050079.776 744RM 4,125.00
F-35-6-30With54277390099.776 770RM 7,370.00

Compare similar models

CENT 5430, keyp., 30X2ml CH
Available soon
Eppendorf CENT 5430, Keyp., 30 × 2 mL CH

RM 31,905.50

Inc. GST

Manufacturer P/N

5427000294

Part Number

4.721 137

Manufacturer

Eppendorf

Depth

420 mm

Microcentrifuge 5430 R incl.rotor FA-45-30-11 with keypad, 230 V / 50-60 Hz

Manufacturer P/N

5428000015

Part Number

9.776 736

Manufacturer

Eppendorf

Depth

640 mm

Micro centrifuges 5430 FA 45-30-11, with rotor 230V, 50-60Hz

Manufacturer P/N

5427000216

Part Number

9.776 730

Manufacturer

Eppendorf

Depth

420 mm

CENT 5430R KEYP, 30x2ML AT-RTR 230V CH
Available soon
Eppendorf CENT 5430R KEYP, 30 × 2 mL AT-RTR, 230 V CH

RM 60,571.50

Inc. GST

Manufacturer P/N

5428000051

Part Number

4.721 140

Manufacturer

Eppendorf

Depth

640 mm

Centrifuge 5430R, refrigerated membrane keypad, incl. rotor FA-45-30-11, 230V/50-60Hz, UK plug

Manufacturer P/N

5428000066

Part Number

4.700 711

Manufacturer

Eppendorf

Depth

640 mm

Centrifuge 5430 incl. rotor FA-45-30-11, 230V/50-60Hz, UK plug

Manufacturer P/N

5427000267

Part Number

4.700 708

Manufacturer

Eppendorf

Depth

420 mm

More items to explore

Microcentrifuge 5430 / 5430 R (IVD) without rotor, with foil keypad

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU5430 R (IVD)54280002109.776 734RM 58,377.00
EU5430 (IVD)54270000119.776 731RM 28,281.00
CH5430 (IVD)54270000924.721 135RM 28,281.00
UK5430 (IVD)54270000624.700 706RM 28,281.00
CH5430 R (IVD)54280000524.721 141RM 58,377.00
UK5430 R (IVD)54280002604.700 712RM 58,377.00

Microcentrifuge 5430 / 5430 R (IVD) without rotor, with knobs

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU5430 (IVD)54270006159.776 732RM 28,281.00
EU5430 R (IVD)54280006199.776 735RM 58,377.00
CH5430 R (IVD)54280000544.721 143RM 58,377.00
CH5430 (IVD)54270003214.721 139RM 28,281.00
UK5430 R (IVD)54280006604.700 714RM 58,377.00
UK5430 (IVD)54270006664.700 710RM 28,281.00

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 31,905.50

Inc. GST