Representative Image

DOSTMANN Dipping Probe K, 100x0.5mm Class 1, -200...+800°C

Brand:Dostmann

Accuracy class

Ø

Dimensions (ØxL)

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
Accuracy class
1
Cable length
1 m
Ø
0.5 mm
Dimensions (ØxL)
0.5 x 100 mm
For
P700, P705, P710, P715, P750, P755, P755-Log, P770, P770-Log
Length
100 mm
Max. temperature
800 °C
Min. temperature
-100 °C
Sort of probe
Immersion probe
Temperature
-100 ... 800 °C

RM 814.00

Inc. GST

Available soon

Product description

The DOSTMANN Dipping Probe K is a high-precision temperature sensor designed for accurate measurements in various laboratory and industrial applications. With a length of 100mm and a diameter of 0.5mm, this Class 1 probe operates efficiently within a temperature range of -200°C to +800°C, ensuring reliable performance across diverse environments.

Key Features:

  • Brand: DOSTMANN
  • Sensor Type: Type K, Class 1
  • Dimensions: 100mm length x 0.5mm diameter
  • Temperature Range: -200°C to +800°C
  • Accuracy: ±0.3°C
  • Compatibility: Suitable for P700, P705, P710, P715, P750, P755, P755-Log, P770, and P770-Log series instruments
  • Manufacturer Article Number: 6010-1001
  • Part Number: 9.851 944

This dipping probe is an essential tool for professionals requiring precise and consistent temperature readings in their processes.



Frequently Asked Questions

1. What is the DOSTMANN Dipping Probe K, 100x0.5mm Class 1, -200 to +800°C used for?

It is a high-precision temperature sensor designed for accurate measurements in various laboratory and industrial applications. With a length of 100mm and a diameter of 0.5mm, this Class 1 probe operates efficiently within a temperature range of -200°C to +800°C, ensuring reliable performance across diverse environments.

2. Is this product suitable for accurate measurements in various laboratory and industrial applications?

Yes. It is designed for accurate measurements in various laboratory and industrial applications, and offers dimensions of 100mm length x 0.5mm diameter and an accuracy of ±0.3°C to support this kind of work.

3. What dimensions and accuracy does this product have?

It has dimensions of 100mm length x 0.5mm diameter, an accuracy of ±0.3°C and a manufacturer article number of 6010-1001.

4. What is this product compatible with?

It is compatible with P700, P705, P710, P715, P750, P755, P755-Log, P770, and P770-Log series instruments. It also offers type K, Class 1 and -200°C to +800°C.

Compare similar models

Dipping probe K, 100x0,5mm class 1, -200...+800°C

Manufacturer P/N

6010-1011

Part Number

7.651 607

Manufacturer

Dostmann

Accuracy class

1

Immersion probe K, 300x1,5mm cl. 1, -100...+1100°C

Manufacturer P/N

6010-1006

Part Number

9.851 949

Manufacturer

Dostmann

Accuracy class

1

Immersion/Insertion probe type K cl.2, -40...+400°C, 120x3,5mm

Manufacturer P/N

6010-1016

Part Number

6.251 199

Manufacturer

Dostmann

Accuracy class

2

Immersion probe K, 300x3mm cl.1, -100...+1100°C

Manufacturer P/N

6010-1010

Part Number

9.851 951

Manufacturer

Dostmann

Accuracy class

1

Immersion sensor type K class 1, -100...+1100°C, 500x3, 0mm

Manufacturer P/N

6010-1007

Part Number

6.224 574

Manufacturer

Dostmann

Accuracy class

1

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 814.00

Inc. GST