Representative Image

BRAND Robot Filter Tips LH Station PAL Tip Rack, 10–100µl Non-Sterile, Pack of 960

Brand:BRAND

Capacity

Sterile

Specifications

Compare models
HS Code #
39269097
ATP-free
Yes
Capacity
10 ... 100 µl
Endotoxin free
Yes
Material
PP
RNase/ DNase-free
Yes
Sterile
No
UNSPSC
41121600

RM 1,067.00

Inc. GST

Available soon

Product description

The BRAND Robot Filter Tips LH Station PAL Tip Rack 10–100µl Non-Sterile are designed for high-precision liquid handling in automated laboratory systems. These tips are compatible with LH Station PAL robotic platforms and ensure consistent and reliable pipetting performance. Made from high-quality materials, they are ideal for high-throughput workflows and offer excellent fit and function without sterility requirements. Each pack includes 960 tips arranged in convenient racks for efficient lab use.

Key Features:

  • Brand: BRAND
  • Volume Range: 10–100µl
  • Compatibility: Designed for LH Station PAL robotic pipetting systems
  • Format: Tip rack for convenient loading
  • Sterility: Non-sterile – ideal for general lab use
  • Packaging: Pack of 960 tips
  • Application: Suitable for automated liquid handling in research and diagnostic laboratories

These robot filter tips are a dependable choice for labs seeking precise and efficient automated pipetting with PAL robotic systems.

Downloads

Compare similar models

Robot filter tips LH-Station pal.  Tip-Rack, 10-100 µl, non-sterile, pack of 960

Manufacturer P/N

734650

Part Number

4.685 523

Manufacturer

BRAND

Capacity

10 ... 100 µl

Robot filter tips LH-Station pal.DE-M  Tip rack, 0.1-20 µl, non-steril, pack of 960

Manufacturer P/N

733646

Part Number

4.685 522

Manufacturer

BRAND

Capacity

1 ... 20 µl

Robot filter tips LH station pal.  Tip-Rack, 10-200 µl, non-sterile, pack of 960

Manufacturer P/N

734652

Part Number

4.685 524

Manufacturer

BRAND

Capacity

10 ... 200 µl

Robot filter tips LH-Station pal.  Tip-Rack, 40-1000 µl, non-steril, pack of 960

Manufacturer P/N

734654

Part Number

4.685 525

Manufacturer

BRAND

Capacity

40 ... 1000 µl

Robot filter tips LH station pal.  Tip-Rack, 1-20 µl, BIO-CERT, pack of 960

Manufacturer P/N

733666

Part Number

4.685 526

Manufacturer

BRAND

Capacity

1 ... 20 µl

Robot filter tips LH-Station pal.  Tip-Rack, 10-100 µl, BIO-CERT, pack of 960

Manufacturer P/N

734670

Part Number

4.685 527

Manufacturer

BRAND

Capacity

10 ... 100 µl

Robot filter tips LH station pal.  Tip rack, 10-200 µl, BIO-CERT, pack of 960

Manufacturer P/N

734672

Part Number

4.685 528

Manufacturer

BRAND

Capacity

10 ... 200 µl

Robot tips LH-Station pal.  Tip-Rack, 40-1000 µl, BIO-CERT, pack of 960

Manufacturer P/N

734674

Part Number

4.685 529

Manufacturer

BRAND

Capacity

40 ... 1000 µl

More items to explore

Robotic tips, PP, racked in TipRack, BIO-CERT®

ProductCapacityMaterialMfr#Part#AvailabilityPrice
1 ... 50 µlPP7331464.685 514RM 797.50
10 ... 200 µlPP7341484.685 515RM 638.00
10 ... 300 µlPP7341504.685 516RM 638.00
40 ... 1000 µlPP7341524.685 517RM 638.00
1 ... 50 µlPP7331664.685 518RM 902.00
10 ... 200 µlPP7341684.685 519RM 847.00
10 ... 300 µlPP7341704.685 520RM 847.00
40 ... 1000 µlPP7341724.685 521RM 847.00

Frequently asked questions

It are designed for high-precision liquid handling in automated laboratory systems. These tips are compatible with LH Station PAL robotic platforms and ensure consistent and reliable pipetting performance. Made from high-quality materials, they are ideal for high-throughput workflows and offer excellent fit and function without sterility requirements. Each pack includes 960 tips arranged in convenient racks for efficient lab use.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story