Representative Image

Bohlender b.safe Waste Cap S60 Electronic Fill-Level Control 3x UNF1/4", 1x GL14, Thread S 60

Brand:Bohlender

Capillary connections

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
Capillary connections
3
Connection for exhaust filter
1
Material
PP
No. of blind plugs
2
No. of fittings
3 x 1,6/ 2,2/ 3,2 mm
No. of olives
0
Thread
S 60
UNSPSC
41115700

RM 2,761.00

Inc. GST

Available soon

Product description

The Bohlender b.safe Waste Cap S60 Electronic Fill-Level Control is designed for precise waste management in laboratory settings. It features a robust, high-quality polypropylene (PP) construction with a freely movable PTFE insert. Depending on the version, it supports connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, and hose olives for tubing with inner diameters from 5.5 to 8 mm. The cap is equipped with three UNF 1/4” fittings and one GL14 connection for an exhaust filter (sold separately). A permanently mounted 400 mm cable connects to the b.safe display for monitoring fill levels, while a red indicator pin provides convenient visual fill-level monitoring. A suitable grounding cable must be ordered separately for grounding purposes.

Key Features:

  • Brand: Bohlender
  • Material: High-quality polypropylene (PP) for durability
  • Connections: 3x UNF 1/4” fittings, 1x GL14 for exhaust filter
  • Compatibility: Supports capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing (I.D. 5.5 to 8 mm)
  • Application: Ideal for laboratory waste management with electronic fill-level control
  • Includes: Fittings, blind fitting, and hose olive (NPT 1/8")
  • Additional Features: Permanently mounted 400 mm cable for b.safe display connection, red indicator pin for visual fill-level monitoring, optional grounding cable (sold separately)
  • Packaging: Sold individually

Scope of Supply:

  • Fittings (UNF 1/4“)
  • Blind fitting (UNF 1/4“)
  • Hose olive (NPT 1/8")

Enhance your laboratory's waste control systems with this reliable and efficient fill-level control cap from Bohlender.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockRM 737.00
PPMM 506-026.313 840In stockRM 940.50
PPLM 506-036.313 841In stockRM 1,204.50

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618RM 121.00
PTFE45 mmM 503-054.681 619RM 236.50
PP30 mmM 503-084.681 620RM 115.50
PP32 mmM 503-094.681 621RM 99.00
PP23 mmM 503-104.681 622RM 99.00
PP26 mmM 503-114.681 623RM 99.00
PP26 mmM 503-124.681 624RM 99.00
PP30 mmM 503-134.681 625RM 99.00
PP36 mmM 503-144.681 626RM 99.00
PTFE45 mmM 503-154.681 627RM 247.50
PP40 mmM 503-164.681 628RM 104.50
PP48 mmM 513-014.681 643RM 99.00
PP41 mmM 513-024.681 644RM 99.00
PP30 mmM 518-014.681 647RM 110.00

Compare similar models

b.safe Waste Cap S60 Electronic Fill-Level Control 3x UNF1/4", 1x GL14

Manufacturer P/N

M 206-60

Part Number

4.681 574

Manufacturer

Bohlender

Capillary connections

3

b.safe Waste Cap S60 Electronic Fill-Level Control 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 206-61

Part Number

4.681 575

Manufacturer

Bohlender

Capillary connections

2

Frequently asked questions

It is designed for precise waste management in laboratory settings. It features a robust, high-quality polypropylene (PP) construction with a freely movable PTFE insert. Depending on the version, it supports connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, and hose olives for tubing with inner diameters from 5.5 to 8 mm. The cap is equipped with three UNF 1/4” fittings and one GL14 connection for an exhaust filter (sold separately). A permanently mounted 400 mm cable connects to the b.safe display for monitoring fill levels, while a red indicator pin provides convenient visual fill-level monitoring. A suitable grounding cable must be ordered separately for grounding purposes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 2,761.00

Inc. GST