Representative Image

Bohlender b.safe Waste Cap GL45 with Funnel – UNF ¼", GL14 & NPT ⅛" Connections

Brand:Bohlender

Specifications

HS Code #
39235090
Capillary connections
1
Connection for exhaust filter
1
Hose connections
1
Material
PPS
No. of fittings
1 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
GL 45
UNSPSC
41115700

RM 2,508.00

Inc. GST

Available soon

Product description

The Bohlender b.safe Waste Cap GL45 with Funnel is designed for secure and efficient waste disposal in laboratory settings. It features a freely movable PTFE insert to ensure leak-proof and flexible connections. The cap includes one UNF1/4" fitting suitable for capillaries with outer diameters of 1.6, 2.2, and 3.2 mm, one GL14 thread compatible with b.safe exhaust air filters (filter not included), and one NPT1/8" hose olive fitting for tubing with inner diameters of 5.5 to 8 mm. The filling funnel, made of polypropylene (PP), is equipped with an integrated automatic stopcock with grip control: the stopcock opens by pushing the grip and closes automatically when the grip is released. The grip position clearly indicates whether the stopcock is open or closed, ensuring safe and controlled fluid transfer. Constructed from durable PPS, the waste cap guarantees chemical resistance and longevity.

Key Features:

  • Brand: Bohlender
  • Material: PPS (Polyphenylene Sulfide) cap, PP funnel
  • Connections: 1x UNF1/4" fitting (for capillaries O.D. 1.6/2.2/3.2 mm), 1x GL14 thread, 1x NPT1/8" hose olive (for tubing I.D. 5.5 to 8 mm)
  • Funnel: Filling funnel with automatic stopcock and grip control
  • Application: Ideal for waste cap and funnel applications in laboratory environments
  • Packaging: Sold individually

Scope of Supply:

  • Filling funnel (automatic stopcock with grip)
  • Fittings (UNF 1/4")
  • Hose olive (NPT 1/8")

This waste cap ensures efficient and secure handling of waste materials, making it an essential tool for laboratories focused on safety and reliability.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockRM 737.00
PPMM 506-026.313 840In stockRM 940.50
PPLM 506-036.313 841In stockRM 1,204.50

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618RM 121.00
PTFE45 mmM 503-054.681 619RM 236.50
PP30 mmM 503-084.681 620RM 115.50
PP32 mmM 503-094.681 621RM 99.00
PP23 mmM 503-104.681 622RM 99.00
PP26 mmM 503-114.681 623RM 99.00
PP26 mmM 503-124.681 624RM 99.00
PP30 mmM 503-134.681 625RM 99.00
PP36 mmM 503-144.681 626RM 99.00
PTFE45 mmM 503-154.681 627RM 247.50
PP40 mmM 503-164.681 628RM 104.50
PP48 mmM 513-014.681 643RM 99.00
PP41 mmM 513-024.681 644RM 99.00
PP30 mmM 518-014.681 647RM 110.00

Compare similar models

b.safe Waste Cap GL45 with Funnel 1x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 345-35

Part Number

4.681 582

Manufacturer

Bohlender

b.safe Waste Cap GL45 with Funnel 1x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 345-25

Part Number

4.681 581

Manufacturer

Bohlender

Frequently asked questions

It is designed for secure and efficient waste disposal in laboratory settings. It features a freely movable PTFE insert to ensure leak-proof and flexible connections. The cap includes one UNF1/4" fitting suitable for capillaries with outer diameters of 1.6, 2.2, and 3.2 mm, one GL14 thread compatible with b.safe exhaust air filters (filter not included), and one NPT1/8" hose olive fitting for tubing with inner diameters of 5.5 to 8 mm. The filling funnel, made of polypropylene (PP), is equipped with an integrated automatic stopcock with grip control: the stopcock opens by pushing the grip and closes automatically when the grip is released. The grip position clearly indicates whether the stopcock is open or closed, ensuring safe and controlled fluid transfer. Constructed from durable PPS, the waste cap guarantees chemical resistance and longevity.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story