Representative Image

Bochem Safety Burner, Propane with Needle Valve, Air Regulation, Pilot Flame, Max. 1300°C, 2.36 KW

Brand:Bochem

Combustible

Gas consumption

Specifications

Compare models
Combustible
Propane
Flame temperature
1300 °C
Gas consumption
180 g/h
Height
180 mm
UNSPSC
41102401
With air regulation
Yes
With pilot flame
Yes

RM 1,237.50

Inc. GST

Available soon

Product description

The Bochem Safety Burner, Propane with Needle Valve, Air Regulation, Pilot Flame, Max. 1300°C, 2.36 KW is a high-performance burner designed for precision and safety in laboratory applications. With an adjustable needle valve for controlling gas flow and air regulation for fine-tuned flame control, this burner ensures optimal performance. The pilot flame feature provides added safety, making it suitable for tasks requiring consistent high temperatures up to 1300°C.

Key Features:

  • Brand: Bochem
  • Fuel: Propane for efficient combustion
  • Flame Temperature: Max. 1300°C for high-precision heating
  • Power: 2.36 KW for reliable and consistent performance
  • Safety Features: Includes needle valve, air regulation, and pilot flame for controlled operation
  • Application: Ideal for laboratory heating, testing, and experiments requiring controlled flames

This safety burner is an essential tool for laboratories and research settings requiring precise and safe flame management at high temperatures.



Frequently Asked Questions

1. What is the Bochem Safety Burner, Propane with Needle Valve, Air Regulation, Pilot Flame, Max. 1300°C, 2.36 KW used for?

It is a high-performance burner designed for precision and safety in laboratory applications. With an adjustable needle valve for controlling gas flow and air regulation for fine-tuned flame control, this burner ensures optimal performance. The pilot flame feature provides added safety, making it suitable for tasks requiring consistent high temperatures up to 1300°C.

2. Is this product suitable for laboratory heating, testing, and experiments requiring controlled flames?

Yes. It is designed for laboratory heating, testing, and experiments requiring controlled flames, and offers a flame temperature of max. 1300°C for high-precision heating and a power of 2.36 KW for reliable and consistent performance to support this kind of work.

3. What flame temperature and power does this product have?

It has a flame temperature of max. 1300°C for high-precision heating and a power of 2.36 KW for reliable and consistent performance.

4. What fuel and safety features does this product offer?

It offers propane for efficient combustion and needle valve, air regulation, and pilot flame for controlled operation.

Accessories

Gas lighter

ProductUNSPSCWeightMfr#Part#AvailabilityPrice
4110242650 g16409.018 801In stockRM 33.00

Gas safety tubing, rubber

ProductTemperature resistanceMaterialMfr#Part#AvailabilityPrice
70 °CChloroprene36080509.018 935In stockRM 471.90
70 °CChloroprene36080759.018 937In stockRM 543.40
70 °CChloroprene36081009.018 940In stockRM 629.20
70 °CChloroprene36080609.018 936In stockRM 486.20
70 °CChloroprene36081509.018 945In stockRM 807.95
70 °CChloroprene36082009.018 950RM 807.95
70 °CChloroprene36081259.018 942RM 722.15
70 °CChloroprene36083009.018 960RM 1,322.75

Compare similar models

Safety burner, propane with needle valve, air regulation, pilot flame, max. 1300°C, 2.36 KW

Manufacturer P/N

7410S

Part Number

9.018 389

Manufacturer

Bochem

Combustible

Propane

Safety burner, natural gas with needle valve, air regulation, pilot flame, max. 1300°C, 1.53 KW

Manufacturer P/N

7400S

Part Number

9.018 388

Manufacturer

Bochem

Combustible

Natural gas

More items to explore

Teclu burner, Ms-Ni

ProductFlame temperatureCombustibleMfr#Part#AvailabilityPrice
1300 °CPropane74109.018 378RM 929.50
1300 °CNatural gas74009.018 377RM 1,094.50

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 1,237.50

Inc. GST