Representative Image

Behr Labor-Technik Behr Kjeldahl Digestion Unit K 40 with 40 Sample Slots, 100 mL Vessels, and Fume Collector

Amperage

Max. no. of sample positions

Power supply

Rated capacity

Type

Weight

Width

Specifications

Compare models
HS Code #
90278990
Amperage
10 A
Depth
580 mm
Power supply frequency
50/60 Hz
Height
770 mm
Max. no. of sample positions
40
Max. temperature
430 °C
Max. voltage
230 V·AC
Nominal capacity per position
100 ml
Power supply
230 V·AC, 50/60 Hz , 10 A
Rated capacity
2250 W

RM 43,703.00

Inc. GST

Available soon

Product description

The Behr Labor-Technik Kjeldahl Digestion Unit K 40 is a high-capacity block digestion system designed for simultaneous processing of up to 40 samples. Each position accommodates standard 100 mL micro Kjeldahl digestion vessels, making it ideal for nitrogen determination and other analytical applications requiring precise sample digestion.

Key Features:

  • Brand: Behr Labor-Technik
  • Model: K 40
  • Product Type: Kjeldahl digestion unit
  • Sample Capacity: 40 positions for 100 mL digestion vessels
  • Heating System: High-efficiency heating with individually adjustable positions
  • Fume Management: Equipped with an extraction hood and exhaust collector to safely manage fumes
  • Control Interface: Behr Labor-Technik single-knob control for easy programming, with menu navigation available in multiple languages
  • Programmable Settings: 25 freely configurable programs for block temperature and digestion time
  • Connectivity: USB interface for data transfer and software updates
  • Observation Window: Removable inspection door on the insertion rack allows monitoring of the digestion process

This Behr Labor-Technik digestion unit offers a comprehensive solution for laboratories requiring efficient and safe sample digestion, enhancing productivity and supporting consistent analytical results.



Frequently Asked Questions

1. What is the Behr Labor-Technik Kjeldahl Digestion Unit K 40 used for?

The K 40 is designed for the intended laboratory application. This kjeldahl digestion unit format supports routine laboratory work in that application.

2. What are the main specifications of the K 40?

The main specifications of the K 40 are that the sample capacity is 40 positions for 100 mL digestion vessels and the programmable settings is 25 freely configurable programs for block temperature and digestion time. These are the main selection points to compare with the requirements of the laboratory task.

3. Is the K 40 suitable for the intended laboratory application?

Yes. The K 40 is suitable for the intended laboratory application. The product is designed specifically for that type of work when its stated format and operating characteristics match the laboratory requirement.

4. How does the K 40 connect to other equipment?

The K 40 uses USB interface for data transfer and software updates. This is the main connection detail to match with the rest of the laboratory setup.

Downloads

Compare similar models

Kjeldahl digestion unit in up to 40 places, encl. sample rack, vessels 100 ml and fume collector

Manufacturer P/N

B00632821

Part Number

9.843 905

Manufacturer

Behr Labor-Technik

Amperage

10 A

Kjeldahl digestion unit in up to 16 places, encl. sample rack, vessels 100 ml and fume collector

Manufacturer P/N

B00632829

Part Number

9.843 903

Manufacturer

Behr Labor-Technik

Amperage

8 A

Kjeldahl digestion unit in up to 24 places, encl. sample rack, vessels 100 ml and fume collector

Manufacturer P/N

B00632828

Part Number

9.843 904

Manufacturer

Behr Labor-Technik

Amperage

8 A

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story