Representative Image

Thermo Eutech CON 150 Portable Conductivity Meter Kit

Specifications

HS Code #
90278930
Battery/ rechargeable battery
2 x AA
Conductivity accuracy
±1 % full scale
Conductivity resolution
0.01 µS ... 0.1 mS
Depth
200 mm
Designation ANSI
AA
Dimensions (WxDxH)
83 x 200 x 57 mm
Height
57 mm
IP code
IP 67
No. of batteries/ rechargeable batteries
2
TDS accuracy
±1 % full scale

RM 2,898.50

Inc. GST

Available soon

Product description

The Thermo Eutech CON 150 Portable Conductivity Meter is designed for accurate and efficient conductivity and TDS measurements in various settings, including fieldwork, laboratories, and educational institutions. Its IP67-rated waterproof design ensures durability, while the large three-line LCD provides clear readings of conductivity or TDS with temperature and cell efficiency.

Key Features:

  • Brand: Thermo Eutech
  • Measurement Modes: Conductivity, TDS with temperature
  • Calibration: Auto/manual; 1 point per range, with automatic recognition of standards
  • Conductivity Range: 0 to 200 mS/cm
  • Resolution (Conductivity): 0.01 μS/cm to 0.1 mS/cm
  • Temperature Compensation: Automatic or manual (-10°C to 110°C)
  • Temperature Range: -10°C to +110°C (14.0°F to 230.0°F)
  • Resolution (Temperature): 0.1°C (0.1°F)
  • Accuracy (Temperature): ±0.5°C (±0.9°F)
  • Memory: Stores up to 150 data sets
  • Adjustable Temperature Coefficient: Settable from 0.0% to meet USP methods for non-compensated measurements
  • Adjustable Conductivity-to-TDS Conversion Factor: 0.4 to 1.0
  • IP Rating: IP67 waterproof design
  • Power Supply: Two AA batteries (included) with over 500 hours continuous use; optional AC adapter available
  • Display: Large, three-line LCD showing conductivity or TDS with temperature and cell efficiency
  • Additional Functions: Acoustic indication for necessary recalibration, ready indicator, manual or automatic measurement hold, optional automatic shut-off
  • Grip-Clip™: Innovative clip to secure the electrode to beakers or containers quickly and easily
  • Backlit Display: Enhanced visibility in low light conditions (CON450 model)
  • Extended Memory: Stores up to 500 data sets (CON450 model)
  • Data Output: USB and RS232 outputs for easy data transfer (CON450 model)
  • Real-Time Clock: Built-in clock stamps stored data and calibration with time and date, meeting GLP standards (CON450 model)
  • Dimensions: Meter 20 x 8.3 x 5.7 cm; Boxed 23 x 23 x 7 cm
  • Weight: Meter 0.5 kg; Boxed 0.7 kg

Scope of Supply:

  • Meter
  • Conductivity cell (K = 1.0)
  • Grip-Clip™ electrode holder
  • 2 x AA batteries
  • Hard carry case
  • Calibration solutions: 1413 µS/cm, 12.88 mS/cm, 84 µS/cm KCl standard solutions
  • Deionised rinse water (60 mL)
  • CON45003K model additionally includes USB cable

This meter is ideal for professionals seeking reliable, portable conductivity measurement solutions in a rugged, waterproof design.

More items to explore

Conductivity meter Eutech™ CON 450 Kit

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
CON 450 KitBattery/mains connectionECCONWP45003K6.282 321RM 4,251.50

Frequently asked questions

It is designed for accurate and efficient conductivity and TDS measurements in various settings, including fieldwork, laboratories, and educational institutions. Its IP67-rated waterproof design ensures durability, while the large three-line LCD provides clear readings of conductivity or TDS with temperature and cell efficiency.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story