Representative Image

Testo Lux Probe

Brand:Testo

Specifications

HS Code #
90278910
Cable length
1.4 m
UNSPSC
41111900

RM 2,717.00

Inc. GST

Available soon

Product description

The Testo Lux Probe is a precision instrument designed to measure illuminance levels in various environments, ensuring compliance with workplace lighting standards. It assesses illuminance according to the V-lambda curve, which corresponds to the sensitivity of the human eye in daylight, making it suitable for all common light sources, including white or warm light LEDs (K< 5,000).

Key Features:

  • Brand: Testo
  • Measurement Range: 0 to 100,000 Lux
  • Accuracy: Standard-compliant accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
  • Resolution: 0.1 Lux (< 10,000 Lux); 1 Lux (> 10,000 Lux)
  • Cable Length: 1.4 meters (4.6 feet)
  • Calibration: Includes a calibration protocol for traceable accuracy
  • Compatibility: Must be used with a compatible Testo multifunction measuring instrument (sold separately)

This lux probe is ideal for determining the illuminance in workplaces such as offices, production areas, hospitals, museums, or schools. Its non-slip probe contact surface ensures convenient positioning at the measuring location, and the 1.4-meter cable length allows for measurements without interference from the user's shadow. The clearly structured measurement menu enables intuitive operation, and the intelligent calibration concept ensures exceptional accuracy by requiring only the probe tip to be sent for calibration, keeping the measuring instrument in continuous use.

Frequently asked questions

It is a precision instrument designed to measure illuminance levels in various environments, ensuring compliance with workplace lighting standards. It assesses illuminance according to the V-lambda curve, which corresponds to the sensitivity of the human eye in daylight, making it suitable for all common light sources, including white or warm light LEDs (K< 5,000).

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story