Specifications

Sensor Ø
9 mm
Flow speed
0 ... 30 m/s
Length sensor
230 mm
Max. flow speed
30 m/s
Max. pressure
1100 hPa
Max. relative humidity
95 %
Max. temperature
70 °C
Min. flow speed
0 m/s
Min. pressure
700 hPa
Min. relative humidity
5 %

NTD 45,367

Inc. GST

Available soon

Product description

The Testo Hot-Wire Probe (Digital), with Bluetooth is designed for precise measurement of air velocity, volume flow, air temperature, and humidity in ventilation ducts. Its wireless Bluetooth connectivity allows for convenient data transmission to compatible Testo multifunction measuring instruments, enhancing flexibility during measurements.

Key Features:

  • Brand: Testo
  • Bluetooth Connectivity: Enables wireless data transmission up to 20 meters
  • Measurement Parameters: Air velocity, volume flow, air temperature, and humidity
  • Telescopic Extension: Extendable up to 1.0 m (optionally up to 2.0 m) with high-contrast scaling for easy immersion depth reading
  • Sensor Protection: Rotatable protective cap safeguards the air velocity sensor when not in use
  • Calibration: Intelligent calibration concept requiring only the probe head to be calibrated
  • Power Supply: Operates on 4 x AA batteries
  • Included Accessories: Hot wire probe head, handle adapter, Bluetooth handle, telescope, 4 x AA batteries, and calibration protocol

This probe is ideal for HVAC professionals conducting air quality and velocity measurements in ventilation ducts, ensuring compliance with industry standards and optimal system performance.



Frequently Asked Questions

1. What is the Testo Hot-Wire Probe, with Bluetooth used for?

It is designed for precise measurement of air velocity, volume flow, air temperature, and humidity in ventilation ducts. Its wireless Bluetooth connectivity allows for convenient data transmission to compatible Testo multifunction measuring instruments, enhancing flexibility during measurements.

2. Is this product suitable for precise measurement of air velocity, volume flow, air temperature, and humidity in ventilation ducts?

Yes. It is designed for precise measurement of air velocity, volume flow, air temperature, and humidity in ventilation ducts, and offers enables wireless data transmission up to 20 meters and air velocity, volume flow, air temperature, and humidity to support this kind of work.

3. What bluetooth connectivity and measurement parameters does this product have?

It has the following key features: enables wireless data transmission up to 20 meters, air velocity, volume flow, air temperature, and humidity and extendable up to 1.0 m (optionally up to 2.0 m) with high-contrast scaling for easy immersion depth reading.

4. What sensor protection and calibration does this product offer?

It offers rotatable protective cap safeguards the air velocity sensor when not in use, intelligent calibration concept requiring only the probe head to be calibrated, operates on 4 x AA batteries and hot wire probe head, handle adapter, Bluetooth handle, telescope, 4 x AA batteries, and calibration protocol.

Downloads

More items to explore

Hot wire probe for climate measuring instrument testo 440, wired

ProductMax. temperatureMin. temperatureMfr#Part#AvailabilityPrice
70 °C-20 °C063515726.313 200NTD 44,789

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 45,367

Inc. GST