Representative Image

Rettberg Water Flow Monitor LWW20

Brand:Rettberg

Specifications

Power supply frequency
60 Hz
Max. voltage
230 V
Power supply
230 V, 60 Hz
Type
LWW 20
Type of auxiliary energy
Mains connection
UNSPSC
41110000

RM 6,820.00

Inc. GST

Available soon

Product description

The Rettberg Water Flow Monitor LWW20 is engineered to safeguard laboratory equipment by monitoring coolant water flow. Equipped with a dual platinum electrode sensor housed in 3.3 borosilicate glass, it detects cooling water shortages and automatically shuts off connected devices, such as heaters used in solvent distillation systems. The system emits both optical and acoustic alarms upon detection of insufficient water flow.

Key Features:

  • Brand: Rettberg
  • Power Supply: 230 V / 60 Hz
  • Maximum Load: 16 A / 3.2 kW
  • Sensor Material: 3.3 borosilicate glass with dual platinum electrodes
  • Alarm System: Optical and acoustic signals
  • Connectivity: 10 mm bore tubing connectors
  • Switch Cable Length: 5 meters

Note: Supplied without the stand and accessories shown.

Frequently asked questions

It is engineered to safeguard laboratory equipment by monitoring coolant water flow. Equipped with a dual platinum electrode sensor housed in 3.3 borosilicate glass, it detects cooling water shortages and automatically shuts off connected devices, such as heaters used in solvent distillation systems. The system emits both optical and acoustic alarms upon detection of insufficient water flow.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 6,820.00

Inc. GST