Representative Image

Mettler-Toledo pH/Conductivity Meter SevenDirect SD23 Kit

Specifications

HS Code #
90278930
Conductivity accuracy
0.5 % of measured value
Depth
205 mm
Dimensions (WxDxH)
195 x 205 x 65 mm
Power supply frequency
50/60 Hz
Height
65 mm
Interfaces
2 x USB-A, 1 x USB-B
IP code
IP 54
Max. pH value
20.000
Max. voltage
240 V
Min. pH value
-2.000

RM 18,238.00

Inc. GST

Available soon

Product description

The Mettler-Toledo pH/Conductivity Meter SevenDirect SD23 Kit offers precise pH and conductivity measurement for a wide range of laboratory and industrial applications. This reliable and easy-to-use system combines high-performance sensors with an intuitive interface, making it ideal for quality control, research, and environmental testing.

Key Features:

  • Brand: Mettler-Toledo
  • Model: SevenDirect SD23 Kit
  • Type: pH/Conductivity meter kit
  • Application: Ideal for laboratory, QC, and environmental analysis
  • Included: SD23 meter, pH and conductivity electrodes, calibration solutions, and accessories
  • Temperature Control: pH electrode InLab Expert Pro-ISM with robust PEEK shaft, integrated NTC 30 kΩ temperature sensor, and ARGENTAL reference system
  • Reference System: Solid XEROLYT reference electrolyte – no refilling needed
  • Operating Temperature: Conductivity sensor InLab 731-ISM with epoxy shaft and NTC 30 kΩ temperature sensor
  • Measuring Range: 4-pole graphite measuring cell eliminates polarization effects and ensures high linearity over a wide conductivity range

Scope of Supply:

  • pH / conductivity meter SevenDirect SD23
  • Electrode arm EasyPlace
  • pH electrode InLab Expert Pro-ISM
  • Conductivity sensor InLab 731-ISM
  • 3 x 2 calibration buffer sachets pH 4.01, 7.00 and 9.21 or 10.01
  • 2 x 2 conductivity standard sachets 1413 µS/cm and 12.88 mS/cm
  • Protective cover
  • Power supply
  • Get-started guide

Deliver accurate and consistent measurements with the Mettler-Toledo SevenDirect SD23 Kit—trusted performance for pH and conductivity analysis.

Accessories

pH electrode InLab® Expert Pro

ProductTypeMax. temperatureMfr#Part#AvailabilityPrice
InLab ® Expert Pro100 °C513431019.041 506In stockRM 2,189.00
InLab ® Expert Pro-ISM100 °C300140969.041 508In stockRM 2,475.00
InLab ® Expert Pro-2m-ISM100 °C513431029.041 507RM 2,590.50

Accessories for benchtop meters SevenDirect™

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Protective cover41115600306715294.684 924RM 473.00
Magnetic stirrer EasyMix™41115600306715704.684 949RM 2,029.50
Power supply 18 W41115600306715804.684 959RM 638.00
Plug set for power supply 18 W41115600306715834.684 961RM 275.00

More items to explore

pH/conductivity meter SevenDirect™ SD23

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
SD23Mains connection306715534.684 935RM 14,575.00

pH/conductivity meter SevenDirect™ SD23 Pure H2O-Kit

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
SD23 Pure H 2 O-KitMains connection306715684.684 947RM 20,069.50

Frequently asked questions

It offers precise pH and conductivity measurement for a wide range of laboratory and industrial applications. This reliable and easy-to-use system combines high-performance sensors with an intuitive interface, making it ideal for quality control, research, and environmental testing.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.