Representative Image

Knick Laboratory pH Meter 766, Set B pH:-2 - +16, mV:-1999 - +1999, -50°C - +150°C, with pH/Pt-1000 Combined Electrode SE 100, Glass, 165 mm

Brand:Knick

Specifications

HS Code #
90278930
Depth
255 mm
Dimensions (WxDxH)
244 x 255 x 95 mm
Height
95 mm
IP code
IP 54
Max. temperature
150 °C
Max. voltage
230 V
Min. temperature
-50 °C
mV range
-1999 ... 1999
mV range accuracy
<0.1 % ±0.3 mV
pH range
-2.00 ... 16.00

RM 11,165.00

Inc. GST

Available soon

Product description

The Knick Laboratory pH Meter 766, Set B, pH -2 - +16, mV -1999 - +1999, -50°C - +150°C, With pH/Pt-1000 Combined Electrode SE 100, Glass, 165 mm is designed for accurate pH, mV and temperature measurement in laboratory applications. Supplied with a mains cable and pH/Pt-1000 SE 100 combination electrode, this set supports reliable routine analysis with a glass 165 mm electrode.

Key Features:

  • Brand: Knick
  • Model: Laboratory pH Meter 766, Set B
  • pH Range: -2 - +16
  • mV Range: -1999 - +1999
  • Temperature Range: -50°C - +150°C
  • Electrode: pH/Pt-1000 combined electrode SE 100
  • Electrode Material: Glass
  • Electrode Length: 165 mm
  • Scope Of Supply: Laboratory pH meter 766, mains cable and pH/Pt-1000 SE 100 combination electrode

The Knick Laboratory pH Meter 766, Set B provides a practical solution for laboratories requiring pH, mV and temperature measurement with a combined pH/Pt-1000 glass electrode.

Downloads

More items to explore

Laboratory pH meter 766

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
766Mains connection7669.774 761RM 8,965.00

Frequently asked questions

The Laboratory pH Meter 766, Set B is designed for accurate pH, mV and temperature measurement in laboratory applications. The stated format and features make the product suitable for routine laboratory work within that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story