Representative Image

Kern & Sohn Digital Coating Thickness Meter TE 1250-0.1FN, 1250 µm

Specifications

HS Code #
90318080
Battery/ rechargeable battery
4 x 1.5 V, AAA
Depth
65 mm
Designation ANSI
AAA
Dimensions (WxDxH)
131 x 65 x 28 mm
Height
28 mm
Max. measured value
1250 µm
Max. voltage battery/ rechargeable battery
1.5 V
Measured range
100 ... 1,250 µm
Min. measured value
100 µm
No. of batteries/ rechargeable batteries
4

RM 2,865.50

Inc. GST

Available soon

Product description

The Kern & Sohn Digital Coating Thickness Meter TE 1250-0.1FN, 1250 µm / 0.1 µm, 1 µm is designed for measuring non-magnetic coatings on iron and steel, as well as coatings on non-magnetic metals. The Offset-Accur function allows precise adjustment to the locally measured range using two-point calibration, supporting improved measurement accuracy of approximately 1 % of the measured value.

Key Features:

  • Brand: Kern & Sohn
  • Product Type: Digital coating thickness meter
  • Model: TE 1250-0.1FN
  • Measuring Range: 1250 µm
  • Resolution: 0.1 µm and 1 µm
  • Application: Suitable for non-magnetic coatings on iron and steel, and coatings on non-magnetic metals
  • Calibration Function: Offset-Accur function with two-point calibration
  • Measuring Units: µm and ml
  • Power Function: Auto-Power-Off
  • Power Supply: Battery operation
  • Data Interface: RS-232
  • Scope Of Supply: Coating thickness gauge, external sensor, base plate, calibration foils, and carrying case

This Kern & Sohn digital coating thickness meter is suitable for inspection and quality control applications requiring precise coating measurement with external sensor operation.

Frequently asked questions

It is designed for measuring non-magnetic coatings on iron and steel, as well as coatings on non-magnetic metals. The Offset-Accur function allows precise adjustment to the locally measured range using two-point calibration, supporting improved measurement accuracy of approximately 1 % of the measured value.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story