Representative Image

Grant Thermostat TX 150, Programmable, RT +5 to 150 °C

Brand:Grant

Specifications

Depth
172 mm
Dimensions (WxDxH)
141 x 172 x 342 mm
Power supply frequency
50/60 Hz
Heating capacity
1840 W
Height
342 mm
Max. delivery pressure
0.31 bar
Max. temperature
150 °C
Max. voltage
230 V
Min. temperature
+5 °C
Power supply
230 V, 50/60 Hz

RM 12,166.00

Inc. GST

Available soon

Product description

The Grant Thermostat TX 150, Programmable, RT +5 to 150 °C, Without Clamp, With Pump is designed as an advanced heating circulator for controlled laboratory temperature applications. It can be combined with a plastic or stainless steel tank, or used independently with an accessory T-clamp. The unit features a modern icon-driven programming interface, full colour display and pump for external circulation.

Key Features:

  • Brand: Grant
  • Product Type: Programmable heating circulator thermostat
  • Model: TX 150
  • Temperature Range: RT +5 to 150 °C
  • Clamp: Supplied without clamp
  • Pump: Includes pump for external circulation
  • Display: Large, bright full colour display
  • Alarm: Visual and audible alarm
  • Timer: 1 minute to 99 hours 59 minutes
  • Calibration: 5 point recalibration
  • Safety: Adjustable over-temperature cut-out
  • Probe: External temperature probe
  • Programming: Remote programming via PC/laptop, 1 program with 30 segments
  • Output: Relay output for control of an external device
  • Interfaces: USB and RS232 interface
  • Cooling Requirement: Additional flow coolers C1G or C2G required for use at or below room temperature
  • Application: Suitable for laboratory heating circulation and temperature control workflows

This Grant TX 150 thermostat is suitable for laboratories requiring programmable heating circulation with external pump capability, colour display and flexible setup options.

Downloads

Accessories

Tanks Optima™ series, stainless steel

ProductTypeCapacityMfr#Part#AvailabilityPrice
ST1212 lST129.905 719RM 4,559.50
ST1818 lST189.905 720RM 5,313.00
ST2626 lST269.905 721RM 5,978.50
ST55 lST59.905 718RM 2,816.00
ST3838 lST389.905 722RM 10,444.50

Accessories for water baths Optima™ series

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
PP spheres PS2041103715PS206.239 419RM 1,067.00
Drain syphon SY141103715SY19.699 096RM 401.50
Heat exchange coil CW541103715CW59.920 764RM 2,200.00
Refrigerated cooler C1GR41103715C1GR4.685 692RM 19,272.00
Refrigerated cooler C2GR41103715C2GR4.685 693RM 21,125.50

More items to explore

Thermostatic controller Optima™ T100

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
T100Mains connectionT1009.699 630RM 7,529.50

Thermostatic controller Optima™ TC120

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
TC120Mains connectionTC1209.699 631RM 9,493.00

Frequently asked questions

It is designed as an advanced heating circulator for controlled laboratory temperature applications. It can be combined with a plastic or stainless steel tank, or used independently with an accessory T-clamp. The unit features a modern icon-driven programming interface, full colour display and pump for external circulation.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

RM 12,166.00

Inc. GST